Skip to main content
Siemens 3VA2163-5MN32-0HH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5MN32-0HH0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-5MN32-0HH0

Siemens SENTRON 3VA2163-5MN32-0HH0, molded case circuit breaker, 3-pole, 63 A, motor protection design, 187 kA interrupting capacity at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5MN32-0HH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-5MN32-0HH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5MN32-0HH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5MN32-0HH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5MN32-0HH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-5MN32-0HH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5MN32-0HH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What it is and what it does

The Siemens SENTRON 3VA2163-5MN32-0HH0 is a 3-pole molded case circuit breaker (MCCB) rated for a continuous current of 63 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. It is specifically designed for motor protection, with integrated phase failure detection and a shunt trip release (STL) for remote tripping. The interrupting capacity hits 187 kA at 240 V AC, 121 kA at 415/440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V, so it handles high-fault utility feeds and downstream coordination in industrial panels. The auxiliary switch block carries 2 auxiliary switches plus 1 trip alarm switch (HQ), giving feedback for PLC status monitoring or remote annunciation. Power loss is a modest 4 W maximum, so heat buildup inside a crowded enclosure stays manageable.

Panel fit and integration

The 3VA2163-5MN32-0HH0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that drops into most SENTRON-compatible mounting plates or DIN-rail adapters. The basic switch variant is 3VA21635MN320AA0, so if you are replacing a unit in an existing panel, verify the base switch matches the installed wiring pattern. The shunt trip (STL) and auxiliary switch block (2 aux + 1 trip alarm) are factory-fitted, saving field-installation labor.

Frequently asked questions

What is the interrupting capacity of this breaker at different voltages?

At 240 V AC it interrupts 187 kA; at 415 V and 440 V it handles 121 kA; at 500 V it manages 75.6 kA; and at 690 V it is rated for 3.7 kA.

Where can I buy 3VA2163-5MN32-0HH0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time.

Does this breaker include phase failure protection?

Yes, phase failure detection is integrated into the motor protection design.

What auxiliary switches are fitted on this unit?

It comes with 2 auxiliary switches plus 1 trip alarm switch (HQ) factory-installed, along with a shunt trip release (STL).

MPN
3VA2163-5MN32-0HH0