Skip to main content
Siemens 3VA2163-5MN32-0HL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5MN32-0HL0 SENTRON MCCB, 63 A, Motor Protect

MPN3VA2163-5MN32-0HL0

Siemens SENTRON molded case circuit breaker, 3VA2163-5MN32-0HL0, 3-pole, 63 A, motor protection version with ETU350M electronic overcurrent release, shunt trip, interrupting capacity 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5MN32-0HL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2163-5MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22

Ratings

3VA2163-5MN32-0HL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.75 W

Protection & Trip Unit

3VA2163-5MN32-0HL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M

Construction & Connection

3VA2163-5MN32-0HL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5MN32-0HL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4

Environmental

3VA2163-5MN32-0HL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5MN32-0HL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

Motor protection MCCB with ETU350M release

The Siemens 3VA2163-5MN32-0HL0 is a SENTRON molded case circuit breaker (MCCB) in the motor protection version, rated for a continuous current Iu of 63 A and carrying an interrupting capacity of 187 kA at 240 V, 121 kA at 415 V, and 75.6 kA at 500 V. The ETU350M electronic overcurrent release provides phase failure detection and adjustable trip settings, making it suited for protecting motor feeders in industrial control panels.

Thermal derating and operating limits

The 63 A rating holds from 40 °C up to 50 °C ambient, then derates to 60.48 A at 55 °C, 59.22 A at 60 °C, 57.96 A at 65 °C, and 56.7 A at 70 °C. Maximum power loss is 75 W. Operating ambient range is -25 °C to 70 °C; storage range is -40 °C to 80 °C. For a panel builder, the derating curve means the breaker can be mounted in a warm enclosure without oversizing, as long as the actual load current stays under the derated value at the expected internal temperature.

Integrated auxiliary and shunt trip

This order code includes a shunt trip (STL) auxiliary release and an integrated auxiliary trip module (3VA9688-0BL30). The auxiliary contact configuration is 2 auxiliary switches plus 1 trip alarm switch plus 1 electrical alarm switch HQ. The shunt trip allows remote tripping via a control signal, which is useful for emergency-stop circuits or remote disconnect in automated lines. The supplied basic switch is 3VA2163-5MN32-0AA0.

Dimensions and panel fit

Dimensions are 105 mm width, 181 mm height, and 86 mm depth. The 3-pole frame fits standard SENTRON panel cutouts and busbar systems. Rated insulation voltage Ui is 800 V. The depth of 86 mm means it will clear most standard enclosure backplates without requiring a deep gland plate.

Frequently asked questions

Where can I buy 3VA2163-5MN32-0HL0?

The part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is the interrupting capacity of 3VA2163-5MN32-0HL0 at 415 V?

The interrupting capacity is 121 kA at 415 V, and the same at 440 V. At 240 V it is 187 kA, at 500 V it is 75.6 kA, and at 690 V it is 17 kA.

What overcurrent release does this MCCB use?

It uses an ETU350M electronic overcurrent release with phase failure detection. The design of the auxiliary release is a shunt trip (STL).

MPN
3VA2163-5MN32-0HL0