Skip to main content
Siemens 3VA2163-5MN32-0KL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5MN32-0KL0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-5MN32-0KL0

Siemens SENTRON 3VA2163-5MN32-0KL0, molded case circuit breaker, 3-pole, 63 A, motor protection design, 187 kA interrupting at 240 V, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5MN32-0KL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21635MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2163-5MN32-0KL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5MN32-0KL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5MN32-0KL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5MN32-0KL0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2163-5MN32-0KL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5MN32-0KL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The interrupting capacity hits 187 kA at 240 V, 121 kA at 415 V, and still 75.6 kA at 500 V, so it handles high-fault utility feeds and large motor branch circuits without cascading upstream.

The 3VA2163-5MN32-0KL0 measures 105 mm wide, 181 mm high, and 86 mm deep — a standard 3-pole MCCB footprint that fits most DIN-rail or panel-mount enclosures. Power loss is 4 W maximum, so heat dissipation is minimal inside a sealed cabinet. The shunt trip release allows remote tripping from a PLC or emergency-stop circuit, and the auxiliary switch complement gives you two form-C contacts for status feedback plus separate trip and alarm signals.

Frequently asked questions

Where can I buy 3VA2163-5MN32-0KL0 and how do I get a price?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing — confirmed at quote time.

What is 3VA2163-5MN32-0KL0's interrupting capacity at 240 V?

The interrupting capacity is 187 kA at 240 V, dropping to 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V.

Does this MCCB include phase failure detection?

Yes, phase failure detection is built into the motor protection design of the 3VA2163-5MN32-0KL0.

What auxiliary switches come with this breaker?

The breaker ships with two auxiliary switches, one trip alarm switch, and one electrical alarm switch — all factory-installed.

MPN
3VA2163-5MN32-0KL0