Skip to main content
Siemens 3VA2163-5MN36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5MN36-0AA0 SENTRON MCCB, 63 A, 121 kA at 415

MPN3VA2163-5MN36-0AA0
Active

Siemens SENTRON 3VA2163-5MN36-0AA0, molded case circuit breaker, 3-pole, 63 A, 121 kA at 415 V, motor protection design, adjustable trip class 10A/10E/20E.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-5MN36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-5MN36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-5MN36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-5MN36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-5MN36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-5MN36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-5MN36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2163-5MN36-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed specifically for motor protection, with a continuous current rating of 63 A that holds flat from 40 °C through 70 °C — no derating needed in a warm enclosure. Its 3-pole construction and adjustable trip class (10A, 10E, 20E) let you match the thermal curve to the motor start profile, so nuisance trips on high-inertia loads are avoided.

The rating drops to 75.6 kA at 500 V and to 3.7 kA at 690 V, so verify your system voltage against the curve before specifying. At 240 V it delivers 187 kA, covering most North American panelboard applications.

Dimensions are 105 mm wide, 181 mm tall, and 86 mm deep — standard SENTRON 3VA form factor for panel integration. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-5MN36-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is 3VA2163-5MN36-0AA0's listed depth?

The listed depth is 86 mm (3.39 in).

What compliance documentation does this brand provide for 3VA2163-5MN36-0AA0?

As a SENTRON product, Siemens provides RoHS, REACH, UL, and IEC compliance documentation — standard for the series.

MPN
3VA2163-5MN36-0AA0