Siemens 3VA2163-5MP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-5MP32-0AA0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-5MP32-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, motor protection design, 3-pole, 63 A rated current, adjustable trip class 10A/10/10E/20/20E/30/30E, breaking capacity 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-5MP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2163-5MP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-5MP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-5MP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-5MP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-5MP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-5MP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Motor protection MCCB with communication and phase-failure detection

The Siemens 3VA2163-5MP32-0AA0 is a SENTRON molded case circuit breaker (MCCB) designed specifically for motor protection, with a rated continuous current of 63 A across the full ambient temperature range from 40 °C to 70 °C — no derating needed up to that ceiling. Its adjustable trip class (Tc CLASS) can be set to 10A, 10/10E, 20/20E, or 30/30E. The breaker includes a communication function and phase-failure detection, so it can report status and trip events to a PLC or BMS without an add-on module.

Breaking capacity and selectivity planning

Rated short-circuit breaking capacity reaches 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V — the 415 V figure is the one most often used for 400 V class panels in IEC markets. With an insulation voltage rating of 800 V, this MCCB can be applied in 690 V systems where the upstream transformer supports it. Dimensions are 181 mm high, 105 mm wide, and 86 mm deep — a standard 3-pole MCCB footprint that fits most Siemens SENTRON distribution panels and retrofit cutouts.

Frequently asked questions

Does this breaker include communication and phase-failure detection?

Yes, it has a communication function and phase-failure detection built in, so it can send trip and status signals to a control system.

MPN
3VA2163-5MP32-0AA0