Skip to main content
Siemens 3VA2163-6HL32-0CA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-6HL32-0CA0 MCCB, 63 A, 242 kA at 240

MPN3VA2163-6HL32-0CA0

Siemens SENTRON 3VA2163-6HL32-0CA0, molded case circuit breaker, 3-pole, 63 A rated continuous current, 242 kA breaking capacity at 240 V, undervoltage release, line protection version.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL32-0CA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-6HL32-0AA0
3VA2163-6HL32-0CA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.6.5 W
3VA2163-6HL32-0CA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2163-6HL32-0CA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL32-0CA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-6HL32-0CA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL32-0CA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2163-6HL32-0CA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with a breaking capacity of 242 kA at 240 V — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream.

How the ratings drive fit

The 63 A rating holds flat from 40 °C to 50 °C, then derates linearly to 53.55 A at 70 °C. That means in a warm panel (say 55 °C ambient) you still get 60.6 A — no need to oversize for typical industrial enclosures. Breaking capacity drops sharply above 500 V: 121 kA at 500 V, 5 kA at 690 V. On a 690 V system this breaker is only good for low-fault locations; for high-rupture 690 V duty, a higher-rated frame is the right call.

Mounts on DIN rail or fixed baseplate. The 105 mm width is three-pole standard for SENTRON 3VA2 frames; leave 10 mm air gap above and below for cooling. No auxiliary contacts or communication module on this variant — the UVR is the only internal accessory. Acceptable for unheated warehouses or outdoor cabinets in temperate climates.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-6HL32-0CA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 3VA2163-6HL32-0CA0's listed depth?

The depth is 86 mm, which fits standard SENTRON panel cutouts.

What is 3VA2163-6HL32-0CA0's listed width?

The width is 105 mm, standard for a 3-pole SENTRON 3VA2 frame.

Will 3VA2163-6HL32-0CA0 drop into a panel specified around 3VA1112-5EF32-0CA0 without rewiring?

Both are SENTRON 3VA frame breakers, so the physical footprint and DIN-rail cutout are identical. However, the 3VA2163-6HL32-0CA0 carries a higher breaking capacity (242 kA at 240 V vs. the 3VA1112's lower rating) and includes an undervoltage release — verify the trip unit and accessory wiring match your panel schematic before swapping.

MPN
3VA2163-6HL32-0CA0