Siemens 3VA2163-6HL32-0DC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HL32-0DC0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2163-6HL32-0DC0

Siemens SENTRON 3VA2163-6HL32-0DC0, molded case circuit breaker, 3-pole, 63 A continuous, adjustable thermal-magnetic trip 95–756 A, interrupting rating 242 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL32-0DC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21636HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2163-6HL32-0DC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-6HL32-0DC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HL32-0DC0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL32-0DC0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-6HL32-0DC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL32-0DC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-6HL32-0DC0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from -25 °C to 70 °C — no derating needed up to that ceiling. The adjustable thermal-magnetic trip unit covers a 95 A minimum to 756 A maximum, giving you a wide coordination window for downstream branch circuits. Interrupting capacity hits 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V, so it handles high-fault utility feeds without cascading upstream.

Panel integration & footprint

The 63 A continuous rating at 40–70 °C means this breaker holds its full ampacity even in a warm panel — no derating curve to calculate. The adjustable trip range (95–756 A) lets you set the magnetic pickup to coordinate with downstream breakers or motor starters, avoiding nuisance trips on inrush while still clearing faults fast. The 242 kA SCCR at 240 V is typical for a high-capacity service entrance breaker; at 690 V the 3.7 kA rating reflects the reduced arc-quenching capability at that voltage, so verify the available fault current at the point of installation.

Frequently asked questions

What is the interrupting rating of 3VA2163-6HL32-0DC0 at 240 V?

The interrupting rating is 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Where can I buy 3VA2163-6HL32-0DC0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

Does 3VA2163-6HL32-0DC0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) and two HQ auxiliary switches.

MPN
3VA2163-6HL32-0DC0