Skip to main content
Siemens 3VA2163-6HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HL32-0DH0 MCCB, 63 A, 3-Pole, 242 kA at 240

MPN3VA2163-6HL32-0DH0

Siemens SENTRON 3VA2163-6HL32-0DH0, molded case circuit breaker, 3-pole, 63 A continuous, 242 kA breaking at 240 V, undervoltage release, 2 auxiliary switches + 1 trip alarm switch HQ.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21636HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-6HL32-0DH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-6HL32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HL32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-6HL32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL32-0DH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2163-6HL32-0DH0 — 63 A MCCB with Undervoltage Release

The Siemens SENTRON 3VA2163-6HL32-0DH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to that ceiling. Per the datasheet, the breaking capacity sits at 242 kA at 240 V AC, dropping to 187 kA at 415 V and 440 V, then to 121 kA at 500 V, and finally 3.7 kA at 690 V.

The 63 A continuous rating is thermally rated — it holds at 40 °C, 45 °C, 50 °C, 55 °C, 60 °C, 65 °C, and 70 °C without adjustment. That means a panel running warm (say 55 °C internal ambient) still gets the full 63 A from this breaker. The minimum breaking current is 95 A, maximum 756 A — that's the range over which the internal trip mechanism operates within its calibrated curve. Below 95 A the breaker may not trip in a defined time; above 756 A it's in the instantaneous region.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-6HL32-0DH0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm position.

What is the depth of 3VA2163-6HL32-0DH0?

The depth is 86 mm (3.39 in). That is the body depth behind the panel face — verify clearance behind the mounting plate.

What is the width of 3VA2163-6HL32-0DH0?

The width is 105 mm (4.13 in), standard for a 3-pole MCCB in this frame class.

Will 3VA2163-6HL32-0DH0 drop into a panel specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are 3-pole SENTRON 3VA frame breakers with the same physical dimensions (105 mm wide, 181 mm high, 86 mm deep), so the mechanical footprint is identical. The wiring difference is in the auxiliary and release configuration — this unit has an undervoltage release and 2 aux switches + 1 trip alarm; the 8HM32 variant may have a different aux/release complement. Check the terminal assignments before assuming a drop-in swap.

MPN
3VA2163-6HL32-0DH0