Siemens 3VA2163-6HL32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HL32-0JH0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2163-6HL32-0JH0

Siemens SENTRON 3VA2163-6HL32-0JH0, molded case circuit breaker, 3-pole, 63 A, interrupting capacity 242 kA at 240 V, line protection, with shunt trip and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21636HL320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-6HL32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-6HL32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HL32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-6HL32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2163-6HL32-0JH0 is a SENTRON molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed up to 70 °C. Interrupting capacity hits 242 kA at 240 V AC, 187 kA at 415 V, and still delivers 121 kA at 500 V.

The 63 A frame is flat-rated across the operating temperature range — no thermal derating curve to calculate below 70 °C. That simplifies panel budgeting: the breaker delivers its full nameplate at the back of a warm enclosure.

The shunt trip (STL) allows remote tripping from an emergency-stop circuit or PLC output. The auxiliary switch block provides two form-C contacts for status feedback and one dedicated trip-alarm contact — enough for a motor control center (MCC) bucket or a distribution panel with remote monitoring.

Frequently asked questions

What is the interrupting capacity of this MCCB?

242 kA at 240 V AC, 187 kA at 415 V, 121 kA at 500 V, and 3.7 kA at 690 V.

Does the 3VA2163-6HL32-0JH0 include a shunt trip?

Yes, it is equipped with a shunt trip (STL) release for remote opening.

Where can I buy 3VA2163-6HL32-0JH0?

This part is sourced to order through independent distribution. Submit an RFQ for current availability and pricing.

MPN
3VA2163-6HL32-0JH0