Skip to main content
Siemens 3VA2163-6HL32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HL32-0KA0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2163-6HL32-0KA0

Siemens SENTRON 3VA2163-6HL32-0KA0, molded case circuit breaker, 3-pole, 63 A continuous, line protection, 242 kA interrupting at 240 V, shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21636HL320AA0
3VA2163-6HL32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-6HL32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HL32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-6HL32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Panel fit and environment

The shunt trip coil requires a control voltage to fire — wire it to an E-stop or a safety relay circuit for remote trip capability. No communication function on this variant, so it's a standalone overcurrent protector with a remote trip input.

Frequently asked questions

Will 3VA2163-6HL32-0KA0 drop into a panel that was specified around 3VA2163-5HL32-0DB0 without rewiring?

Yes — same frame dimensions (105 mm wide, 181 mm tall, 86 mm deep), same three-pole layout, same interrupting ratings. The only difference is the auxiliary release: this one has a shunt trip (STL) instead of an undervoltage release, so the control wiring for the trip coil will differ if the original panel was wired for an undervoltage coil.

MPN