Siemens 3VA2163-6HL36-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HL36-0DL0 SENTRON MCCB, 63 A, 3-Pole, 242 k

MPN3VA2163-6HL36-0DL0

Siemens SENTRON 3VA2163-6HL36-0DL0, molded case circuit breaker, 3-pole, 63 A continuous current, line protection design, breaking capacity 242 kA at 240 V, 187 kA at 415 V, with undervoltage release and auxiliary switches.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-6HL36-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-6HL36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2163-6HL36-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-6HL36-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-6HL36-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-6HL36-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2163-6HL36-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-6HL36-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2163-6HL36-0DL0 — 63 A MCCB with Undervoltage Release

The Siemens SENTRON 3VA2163-6HL36-0DL0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C, with no derating required up to 70 °C — the full 63 A holds across the entire ambient range. Breaking capacity is 242 kA at 240 V AC and 187 kA at 415/440 V, dropping to 121 kA at 500 V and 3.7 kA at 690 V. The UVR ensures the breaker trips on loss of control voltage — critical for machinery where an undervoltage condition must isolate the load. The auxiliary switch complement (2 NO/NC + trip + electrical alarm) provides status feedback for PLC inputs or remote annunciation, supporting a clean audit trail on what state the breaker is in.

The sharp drop to 3.7 kA at 690 V means it is not intended for 690 V line-side applications — it is a 240/415 V rated device. For 690 V systems, a higher-voltage rated frame is needed. The 63 A continuous rating with flat derating to 70 °C simplifies panel thermal budgeting: no need to oversize for elevated ambient temperatures in a sealed enclosure.

The supplied basic switch for this variant is 3VA2163-6HL36-0AA0; the order code 3VA2163-6HL36-0DL0 adds the undervoltage release and the full auxiliary switch complement. If a panel was specified around the 3VA2163-5HL32-0DB0 (a similar 3-pole 63 A frame), verify the auxiliary switch count and UVR presence — the -6HL36-0DL0 carries more aux contacts and a UVR, so it may require additional wiring space but drops into the same mounting footprint.

Physical Integration and Wiring

The 3-pole design occupies a standard 105 mm module width. The undervolture release coil must be wired to the appropriate control voltage; the auxiliary switches are pre-wired to the terminal block on the breaker face. Power loss is 6.5 W maximum — negligible for enclosure heat rise calculations but worth noting for tightly packed cabinets. The 63 A rating is maintained without derating across the full operating range, which simplifies panel design for unconditioned spaces.

Frequently asked questions

Where can I buy the 3VA2163-6HL36-0DL0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote.

What is the breaking capacity at 415 V?

At 415 V AC, the breaking capacity is 187 kA.

Does the 3VA2163-6HL36-0DL0 include an undervoltage release?

Yes, it includes an undervoltage release (UVR) as the auxiliary release, plus two auxiliary switches, one trip alarm switch, and one electrical alarm switch.

MPN
3VA2163-6HL36-0DL0