Skip to main content
Siemens 3VA2163-6HN32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-6HN32-0AH0 SENTRON MCCB, 63 A, 242 kA

MPN3VA2163-6HN32-0AH0

Siemens SENTRON 3VA2 molded case circuit breaker, 3VA2163-6HN32-0AH0, 3-pole, 63 A at 40 °C, 242 kA breaking capacity at 240 V, ETU350 electronic trip unit, line protection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-6HN32-0AH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-6HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-6HN32-0AH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V5 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-6HN32-0AH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout

Construction & Connection

3VA2163-6HN32-0AH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-6HN32-0AH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-6HN32-0AH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-6HN32-0AH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens 3VA2163-6HN32-0AH0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for line protection, carrying 63 A continuously at 40 °C ambient with no derating needed up to 50 °C — the same 63 A holds at 45 °C and 50 °C, then steps down to 60.6 A at 55 °C and 53.6 A at 70 °C. Breaking capacity hits 242 kA at 240 V AC, 187 kA at 415/440 V, and still delivers 121 kA at 500 V, making it a strong choice for high-fault panels where SCCR headroom matters. Three poles, ETU350 electronic trip unit, and a built-in auxiliary contact package (2 auxiliary switches + 1 trip alarm switch HQ) give the panel builder a clean way to signal breaker state back to the PLC or alarm annunciator without adding external relays. Front IP40 keeps dust out of the enclosure cutout; the 86 mm depth and 105 mm width fit standard MCCB panel footprints.

What the ratings mean for fit

The 63 A continuous rating at 40 °C is the number to size against your load current. Because the breaker holds full rating through 50 °C, you get a 10 °C thermal headroom margin before any derating kicks in — useful in a crowded panel where ambient runs warm. The 242 kA interrupting capacity at 240 V means this MCCB can safely clear a fault on a transformer secondary or a large-capacitor bank without upstream fuses needing to coordinate; at 690 V the breaking capacity drops to 5 kA, so verify your system voltage against the curve. The ETU350 electronic trip unit offers adjustable thermal and magnetic settings (not detailed in this listing), which lets the specifying engineer fine-tune the trip curve to the load — motor start vs. resistive heater vs. distribution feeder. The auxiliary switch package (2 form-C + 1 trip alarm) is pre-installed, saving a wiring step during panel build.

Frequently asked questions

What is the breaking capacity of 3VA2163-6HN32-0AH0 at 240 V?

242 kA at 240 V AC. At 415 V and 440 V it delivers 187 kA, at 500 V it's 121 kA, and at 690 V it drops to 5 kA.

Where can I buy 3VA2163-6HN32-0AH0 and how is it quoted?

We source this MCCB through independent distribution and quote it to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Does 3VA2163-6HN32-0AH0 include auxiliary contacts?

Yes, it comes with 2 auxiliary switches plus 1 trip alarm switch (HQ version) built in, so you can monitor breaker status without adding external contact blocks.

MPN
3VA2163-6HN32-0AH0