Skip to main content
Siemens 3VA2163-6HN36-0AJ0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2163-6HN36-0AJ0 MCCB, 63A, 242kA at 240V

MPN3VA2163-6HN36-0AJ0

Siemens SENTRON 3VA2163-6HN36-0AJ0, 3-pole molded case circuit breaker, 63 A continuous rating, 242 kA interrupting capacity at 240 V AC, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-6HN36-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-6HN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11

Ratings

3VA2163-6HN36-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-6HN36-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-6HN36-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-6HN36-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-6HN36-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-6HN36-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA2163-6HN36-0AJ0 is a 3-pole molded case circuit breaker rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating curve to chase. Interrupting capacity hits 242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. That 242 kA at 240 V tells you it's built for high-fault panels where a standard MCCB would weld closed. Line protection design means it's tuned for feeder and distribution duty, not motor-starting curves.

Fit and footprint

Dimensions are 105 mm wide, 181 mm tall, 86 mm deep — a standard SENTRON 3VA2 frame that drops into existing panel cutouts and busbar arrangements without re-drilling. The 86 mm depth leaves room behind the gland plate for cable bends. Operating temperature range is -25 °C to 70 °C; storage from -40 °C to 80 °C. Power loss maxes out at 4 W, so ventilation requirements are minimal even in a sealed enclosure.

Switching and signaling

Comes with 2 auxiliary switches plus 1 trip alarm switch (HP type) built in — gives you remote status on open/closed and fault-trip without adding a separate accessory. Trip indicator is present on the front face, so a walk-by tells you whether it's a manual open or a fault. No undervoltage release, no communication module, no ground-fault monitoring on this variant — it's a straight line-protection breaker with basic signaling.

Frequently asked questions

Where can I buy 3VA2163-6HN36-0AJ0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at that time.

What are the key interrupting ratings for this MCCB?

242 kA at 240 V AC, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 3.7 kA at 690 V. The 242 kA at 240 V is the standout — it handles very high fault currents typical in transformer-secondaries or large busway feeds.

Does this breaker have auxiliary contacts built in?

Yes, it ships with 2 auxiliary switches plus 1 trip alarm switch (HP type) — no separate accessory needed for remote status or fault indication.

What compliance documentation does Siemens provide for this part?

As a current-production SENTRON MCCB, it carries the standard Siemens declarations — RoHS, REACH, and IEC/UL certifications applicable to the 3VA2 series. Specific certificate copies are available on request at quote time.

MPN