Siemens 3VA2163-7HK32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7HK32-0AA0 SENTRON MCCB, 63A, 3-Pole, 242kA

MPN3VA2163-7HK32-0AA0
Active

Siemens SENTRON 3VA2163-7HK32-0AA0, molded case circuit breaker, 3-pole, 63 A, ETU340 electronic trip unit, 242 kA breaking capacity at 415 V AC, line protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7HK32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-7HK32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7HK32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7HK32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7HK32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7HK32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7HK32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The 3-pole construction and ETU340 electronic overcurrent release give it adjustable long-time, short-time, instantaneous, and ground-fault protection curves, which matters when you need selective coordination downstream of a transformer or upstream of a motor control center. Breaking capacity is the headline number here: 242 kA at 415 V AC and 440 V AC, 330 kA at 240 V, 187 kA at 500 V.

Panel fit and physical integration

Front IP40 protection means the breaker is touch-safe on the front face but not sealed against dust ingress into the enclosure; install in a panel with at least IP4X overall.

What the ETU340 trip unit gives you

The ETU340 is an electronic trip unit with LSI protection: long-time (L) for overload, short-time (S) for selective coordination, and instantaneous (I) for short-circuit. It does not include ground-fault monitoring — that's the ETU350 or external add-on. The trip indicator is not fitted on this variant, so no mechanical flag for a tripped state on the breaker face. No undervoltage release, no communication function, no voltage trigger — this is a straight protection device, not a smart breaker. If you need remote signaling or undervoltage protection, you add the accessory modules separately.

Frequently asked questions

Where can I buy 3VA2163-7HK32-0AA0 and what is the lead time?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no fixed stock or lead-time figure is published for this channel.

Will 3VA2163-7HK32-0AA0 drop into a panel specified around 3VA1110-5ED32-0AA0 without rewiring?

No — the 3VA2163 is a larger frame size (105 mm wide, 181 mm tall) than the 3VA1110 series. The 3VA1110 is a 3-pole 100 A frame at 55 mm wide; the 3VA2163 is a 3-pole 250 A frame at 105 mm wide. Panel cutout, busbar spacing, and mounting hole pattern differ. You would need to re-engineer the mounting and bus connections.

What compliance documentation does this breaker carry?

The SENTRON 3VA2 series is designed to IEC 60947-2 and typically carries CE, UKCA, and EAC markings. Specific certification marks (UL, CSA) depend on the exact variant — confirm at quote time if a UL listing is required for your jurisdiction.

MPN