Skip to main content
Siemens 3VA2163-7HM36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7HM36-0AA0 SENTRON MCCB, 63 A, 3-Pole, ETU33

MPN3VA2163-7HM36-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3-pole, 63 A, ETU330 electronic trip, line protection, 330 kA at 240 V, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7HM36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2163-7HM36-0AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7HM36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L-conductor
3VA2163-7HM36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7HM36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7HM36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7HM36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens 3VA2163-7HM36-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) in the line-protection variant, carrying a continuous rated current Iu of 63 A that holds flat from 40 °C through 70 °C — no derating curve to track for a warm panel. The ETU330 electronic trip unit handles the overcurrent release, and the breaker includes summation ground-fault monitoring on the L-conductor. The 330 kA interrupting rating at 240 V (242 kA at 415 V and 440 V, 187 kA at 500 V, 3.7 kA at 690 V) gives serious SCCR headroom for high-fault installations; the 3.7 kA at 690 V is the practical ceiling for 690 V line-side faults.

Deployment context

Mounts in a standard MCCB panel footprint — the 105 mm width and 86 mm depth leave room for side-by-side breakers and busbar connections. The motor-drive option (listed as optional extension) means you can add remote motor operation later without swapping the breaker.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-7HM36-0AA0?

Submit an RFQ through this listing. Pricing and stock are confirmed at quote time; we source through independent distribution and can quote against your required quantity and delivery window.

What is the interrupting rating of this MCCB at different voltages?

330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The 690 V figure is the limiting case for high-voltage line-side faults.

Does the 3VA2163-7HM36-0AA0 include ground-fault protection?

Yes, it has summation ground-fault monitoring on the L-conductor, integrated into the ETU330 trip unit.

MPN
3VA2163-7HM36-0AA0