Skip to main content
Siemens 3VA2163-7HN32-0BA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA2163-7HN32-0BA0 MCCB, 63 A, 3-Pole, 330 kA at 240

MPN3VA2163-7HN32-0BA0

SENTRON 3VA2163-7HN32-0BA0, molded case circuit breaker, 3-pole, 63 A, line protection, 330 kA at 240 V, with undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7HN32-0BA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7HN32-0AA0
3VA2163-7HN32-0BA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-7HN32-0BA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7HN32-0BA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7HN32-0BA0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7HN32-0BA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7HN32-0BA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The SENTRON 3VA2163-7HN32-0BA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Breaking capacity climbs to 330 kA at 240 V, drops to 242 kA at 415 V and 440 V, then 187 kA at 500 V, and falls off sharply to 3.7 kA at 690 V. No auxiliary switch, no ground-fault monitoring, no communication function on this variant. It's a straight line-protection breaker with undervoltage supervision, period.

Depth of 86 mm means it clears most standard gland plates and backpanel wiring troughs, but check your enclosure depth if you're retrofitting into a shallow box.

Frequently asked questions

Does this breaker include an undervoltage release?

Yes, it comes with an undervoltage release (UVR) as the auxiliary release type.

MPN
3VA2163-7HN32-0BA0