Skip to main content
Siemens 3VA2163-7HN32-0CL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7HN32-0CL0 SENTRON MCCB, 63 A, 330 kA at 240

MPN3VA2163-7HN32-0CL0

Siemens SENTRON 3VA2163-7HN32-0CL0, molded case circuit breaker, 3-pole, 63 A, ETU350 electronic release, line protection, 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7HN32-0CL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2163-7HN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2163-7HN32-0CL0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.6375 A
Current at 60 °C58.275 A
Current at 65 °C55.9125 A
Current at 70 °C53.55 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V5.25 kA
Power loss, max.6.5 W
3VA2163-7HN32-0CL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
3VA2163-7HN32-0CL0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7HN32-0CL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2163-7HN32-0CL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7HN32-0CL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

63 A MCCB with ETU350 — high interrupting capacity for line protection

The Siemens SENTRON 3VA2163-7HN32-0CL0 is a 3-pole molded case circuit breaker rated for 63 A continuous current with an ETU350 electronic trip unit, configured for line protection. Its interrupting capacity reaches 330 kA at 240 V and 242 kA at 415 V, which means it can safely clear very high fault currents typical of large transformer secondaries or bus-duct feeds without cascading upstream — the kind of SCCR headroom a site electrical engineer needs for a selective coordination study. The breaker carries a 20 000-cycle mechanical endurance, so it holds up in frequent-switching applications like pump or compressor panels where the disconnect is cycled daily. The auxiliary contact configuration is 2 auxiliary switches plus 1 trip alarm and 1 electrical alarm switch (HQ type), giving the PLC or BMS four discrete status points: open/closed, tripped on fault, and a separate electrical alarm signal.

The breaker holds its full 63 A rating up to 50 °C ambient; above that it derates linearly to 53.55 A at 70 °C. In a sealed, non-ventilated enclosure the panel builder should account for the 6.5 W maximum power loss when sizing internal temperature rise. Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA footprint that drops into existing DIN-rail or screw-mount panel layouts without re-drilling.

Frequently asked questions

What is the interrupting capacity of this MCCB at 415 V?

242 kA at 415 V, which is the same rating as at 440 V; at 500 V it drops to 187 kA, and at 690 V to 5.25 kA.

What does the ETU350 trip unit do on this breaker?

The ETU350 is an electronic overcurrent release that provides adjustable long-time, short-time, instantaneous, and ground-fault protection (though this variant ships without ground-fault monitoring). It enables selective coordination with downstream breakers by allowing a deliberate short-time delay.

Where can I buy 3VA2163-7HN32-0CL0 and what is the lead time?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead-time and price quote.

Will 3VA2163-7HN32-0CL0 drop into a panel specified around 3VA2163-5HL32-0DB0?

Both are 3VA2 frame size breakers with the same 105 mm width and 86 mm depth, so the mechanical footprint is identical. The difference is the trip unit: the -7HN32-0CL0 uses an ETU350 electronic release, while the -5HL32-0DB0 uses a different release variant. Check the trip settings and auxiliary contact wiring before swapping — the undervoltage release and auxiliary contact configuration may differ.

MPN
3VA2163-7HN32-0CL0