The interrupting capacity reaches 330 kA at 240 V AC and stays at 242 kA through 415–440 V, then drops to 187 kA at 500 V and 3.7 kA at 690 V — so on a 400 V distribution board this breaker handles fault currents up to 242 kA without needing an upstream current-limiting fuse.

SENTRON 3VA2163-7JP32-0AA0 MCCB, 63 A, 3-Pole, ETU550
SENTRON 3VA2163-7JP32-0AA0, molded case circuit breaker, 3-pole, 63 A continuous, ETU550 electronic trip unit, interrupting capacity 330 kA at 240 V AC.
Specifications
| Parameter | Value |
|---|---|
| Product designation | Molded case circuit breaker |
| Brand / range | SENTRON |
| Parameter | Value |
|---|---|
| Number of poles | 3 |
| Rated operational voltage Ue (AC) | 690 V |
| Rated insulation voltage Ui | 800 V |
| Current at 40 °C | 63 A |
| Current at 45 °C | 63 A |
| Current at 50 °C | 63 A |
| Current at 55 °C | 63 A |
| Current at 60 °C | 63 A |
| Current at 65 °C | 63 A |
| Current at 70 °C | 63 A |
| Switching capacity class | C |
| Breaking capacity at 240 V | 330 kA |
| Breaking capacity at 415 V | 242 kA |
| Breaking capacity at 440 V | 242 kA |
| Breaking capacity at 500 V | 187 kA |
| Breaking capacity at 690 V | 3.7 kA |
| Power loss, max. | 4 W |
| Parameter | Value |
|---|---|
| Overcurrent release (trip unit) type | ETU550 |
| Overcurrent protection function | LSI |
| Ground-fault monitoring | Without |
| Grounding protection function | No |
| Parameter | Value |
|---|---|
| Main circuit connection type | on both sides nut keeper kit |
| Main circuit connector arrangement | Front terminal |
| Protection class (IP), front | IP40 |
| Parameter | Value |
|---|---|
| Undervoltage release | No |
| Voltage trigger | No |
| Trip indicator | No |
| Communication function | Yes |
| Measurement function | No |
| Motor drive option | Yes |
| Auxiliary CO contacts | 0 |
| Parameter | Value |
|---|---|
| Operating temperature, max. | 70 °C |
| Operating temperature, min. | -25 °C |
| Storage temperature, max. | 80 °C |
| Storage temperature, min. | -40 °C |
| Parameter | Value |
|---|---|
| Mechanical service life (operating cycles), typ. | 25 000 |
| Height | 181 mm |
| Width | 105 mm |
| Depth | 86 mm |
| Height (in) | 7.13 in |
| Width (in) | 4.13 in |
| Depth (in) | 3.39 in |
Product details
Frequently asked questions
Where can I buy 3VA2163-7JP32-0AA0 and how do I get a price?
This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.
What is 3VA2163-7JP32-0AA0's listed depth (86 mm) on this component line?
The depth is 86 mm (3.39 in), width 105 mm (4.13 in), height 181 mm (7.13 in).
What compliance documentation does this brand provide for 3VA2163-7JP32-0AA0 (RoHS, REACH, UL, IEC)?
As a SENTRON MCCB, it carries UL and IEC certifications standard for the series. RoHS and REACH declarations are available from the manufacturer upon request.