Skip to main content
Siemens 3VA2163-7KP36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7KP36-0AA0 SENTRON MCCB, 63 A, 3-pole, ETU85

MPN3VA2163-7KP36-0AA0
Active

Siemens SENTRON 3VA2 series, 3VA2163-7KP36-0AA0 molded case circuit breaker, 3-pole, 63 A rated, ETU850 electronic trip unit, 330 kA interrupting at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7KP36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-7KP36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7KP36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7KP36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7KP36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7KP36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7KP36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

63 A MCCB with ETU850 — 330 kA interrupting at 240 V

The interrupting ratings are the headline: 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The trip range spans 95 A minimum to 756 A maximum, covering motor feeders, transformer primaries, and general distribution. Communication function is onboard, enabling integration with energy management or remote monitoring systems — useful for a plant engineer tracking load profiles without a panel walk.

The IP40 front protection suits indoor switchboard installation; the breaker mounts via the standard SENTRON 3VA2 baseplate or direct screw fixing. Power loss is 4 W maximum, low enough that ventilation spacing in a typical distribution panel is sufficient — no forced cooling required for this single unit.

Frequently asked questions

What is the interrupting capacity of 3VA2163-7KP36-0AA0 at 240 V?

330 kA at 240 V AC, with 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V.

What trip unit does 3VA2163-7KP36-0AA0 use?

The ETU850 electronic trip unit with adjustable protection curves and a trip range of 95 A to 756 A.

Where can I buy 3VA2163-7KP36-0AA0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2163-7KP36-0AA0