Skip to main content
Siemens 3VA2163-7KQ42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7KQ42-0AA0 SENTRON MCCB, 63 A, 4-pole, 330 k

MPN3VA2163-7KQ42-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 63 A, 4-pole, line protection, ETU860 electronic trip unit, 330 kA interrupting at 240 V AC.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7KQ42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2163-7KQ42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.8 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7KQ42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860

Construction & Connection

3VA2163-7KQ42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7KQ42-0AA0 — Accessories & Functions
ParameterValue
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-7KQ42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7KQ42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

What this MCCB delivers

The Siemens 3VA2163-7KQ42-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) rated for 63 A continuous current at 40 °C through 70 °C — no derating needed across that full ambient range, which simplifies panel design in warm enclosures. Four poles, line-protection version, with an ETU860 electronic trip unit that supports communication and ground-fault monitoring via summation of L+N conductor current. Interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.8 kA at 690 V — the 690 V figure is notably lower, so verify the available fault current at that voltage. Rated insulation voltage is 800 V.

Integration and mounting

Mounts in a standard panel footprint: 181 mm high, 140 mm wide, 86 mm deep. Front face carries IP40 protection — fine for a clean indoor panel; keep the enclosure door closed during washdown. The ETU860 trip unit includes a communication function, so you can wire it into a higher-level monitoring system without an add-on module. N-conductor protection is adjustable: OFF, 40 %, or up to 160 % of the phase rating. Adjustable response time (tr) ranges from 0.5 s to 25 s.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-7KQ42-0AA0?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

What are the key ratings of 3VA2163-7KQ42-0AA0?

Rated continuous current 63 A, 4-pole, interrupting capacity 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, 3.8 kA at 690 V. ETU860 electronic trip unit with communication and ground-fault monitoring.

What compliance documentation does this brand provide for 3VA2163-7KQ42-0AA0?

The evidence does not list specific compliance documents (RoHS, REACH, UL, IEC). Standard Siemens SENTRON MCCB documentation typically includes a declaration of conformity; confirm with your Siemens contact or request it with your RFQ.

MPN
3VA2163-7KQ42-0AA0