Skip to main content
Siemens 3VA2163-7MN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN32-0AB0 SENTRON MCCB, 63 A, 3-Pole, 330 k

MPN3VA2163-7MN32-0AB0

Siemens SENTRON 3VA2163-7MN32-0AB0, molded case circuit breaker, 3-pole, 63 A, motor protection design, 330 kA interrupting capacity at 240 V, 2 auxiliary switches HP.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2163-7MN32-0AB0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MN32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-7MN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MN32-0AB0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Integrator's first look

The Siemens SENTRON 3VA2163-7MN32-0AB0 is a 3-pole molded case circuit breaker rated for a full 63 A continuously from 40 °C through 70 °C — no derating curve to chase across the operating band. That flat thermal profile matters when the breaker shares a crowded enclosure with other heat sources. Interrupting capacity hits 330 kA at 240 V, stepping down to 242 kA at 415 V and 440 V, then 187 kA at 500 V. At 690 V it still clears 3.7 kA — enough for most industrial service entrances but worth verifying against the available fault current at the point of installation. Designed specifically for motor protection, it includes phase failure detection as a built-in function — no add-on module required. The 2 auxiliary switches (HP type) provide status feedback for the PLC or HMI without occupying extra panel space.

Panel fit and integration

Dimensions are 105 mm wide by 181 mm tall by 86 mm deep — a standard 3-pole MCCB footprint that drops into most SENTRON panelboards and distribution blocks without re-drilling. The 86 mm depth leaves room behind the gland plate for wiring without forcing a deeper enclosure. Power loss is capped at 4 W maximum, which keeps internal cabinet temperature rise manageable even in sealed enclosures. The -25 °C to +70 °C operating range covers most indoor industrial environments; storage range extends from -40 °C to +80 °C for warehouse cycling.

Coordination and selectivity notes

The 3VA2163-7MN32-0AB0 ships without undervoltage release, ground-fault monitoring, or communication function — it is a straight thermal-magnetic motor protection breaker. The trip indicator is also absent, so fault indication relies on the auxiliary switch feedback or a separate indicating light. Short-time delay settings are available: minimum 4 s, maximum 17 s, allowing selective coordination with downstream branch breakers on motor starting inrush. The base switch variant is 3VA2163-7MN32-0AA0; this order code adds the 2 HP auxiliary switches.

Frequently asked questions

What is the depth of this breaker?

The listed depth is 86 mm (3.39 inches), which fits standard SENTRON panelboard and distribution block layouts.

Does this breaker include ground-fault protection?

No, this variant ships without ground-fault monitoring. It is a straight thermal-magnetic motor protection breaker without undervoltage release or communication function.

MPN
3VA2163-7MN32-0AB0