Skip to main content
Siemens 3VA2163-7MN32-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN32-0AF0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-7MN32-0AF0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2163-7MN32-0AF0, 63 A, 3-pole, motor protection design, 330 kA interrupting at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MN32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-7MN32-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MN32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MN32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MN32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-7MN32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MN32-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

63 A MCCB for motor protection — what the ratings mean for fit

The Siemens 3VA2163-7MN32-0AF0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) designed specifically for motor protection, with a continuous current rating of 63 A that holds flat across the full 40 °C to 70 °C ambient range — no derating needed in a warm enclosure. Its interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — figures that tell you this breaker is built for high-fault-current industrial distribution, not light commercial service. The motor-protection design includes phase failure detection, a trip indicator, and a 1 auxiliary switch plus 1 trip alarm switch (HQ type) for remote status feedback.

Panel fit and integration

The 3-pole breaker measures 105 mm wide, 181 mm high, and 86 mm deep — a compact footprint that fits standard 3-pole MCCB panel cutouts and leaves room for side-mounted auxiliary wiring. Operating temperature range spans -25 °C to 70 °C, with storage from -40 °C to 80 °C; maximum power loss is 4 W, manageable in a sealed enclosure without forced ventilation. The basic switch variant is order code 3VA2163-7MN32-0AA0, and this unit ships with the HQ auxiliary switch block pre-installed — no field assembly required for the alarm contact.

Frequently asked questions

What auxiliary contacts come with this unit?

It ships with one auxiliary switch and one trip alarm switch (HQ type) pre-installed, providing both status and fault indication without separate ordering.

MPN
3VA2163-7MN32-0AF0