Siemens 3VA2163-7MN32-0AG0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN32-0AG0 SENTRON MCCB, 63A 3-Pole Motor Pr

MPN3VA2163-7MN32-0AG0

Siemens SENTRON 3VA2163-7MN32-0AG0 molded case circuit breaker, 3-pole, 63 A motor protection design, 330 kA interrupting capacity at 240 V AC, 86 x 105 x 181 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7MN32-0AG0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2163-7MN32-0AG0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7MN32-0AG0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7MN32-0AG0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MN32-0AG0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA2163-7MN32-0AG0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MN32-0AG0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-7MN32-0AG0 is a 3-pole molded case circuit breaker (MCCB) designed specifically for motor protection, rated at 63 A continuously from 40 °C through 70 °C ambient — no derating needed across that span.

Interrupting capacity and footprint

Interrupting capacity hits 330 kA at 240 V, 242 kA at 415/440 V, 187 kA at 500 V, and 3.7 kA at 690 V — that 690 V figure is the weak link; verify your system voltage against the curve. Dimensions are 86 mm deep, 105 mm wide, 181 mm tall (3.39 x 4.13 x 7.13 in). The 105 mm width means it occupies three standard 35 mm DIN-rail modules; check fill factor if retrofitting into a crowded panel.

Built-in auxiliaries and trip alarm

Trip indicator is present for quick visual fault identification.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-7MN32-0AG0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA2163-7MN32-0AG0 drop into a panel that was specified around 3VA2163-8HM32-0AA0 without rewiring?

Both are 3-pole SENTRON MCCBs in the same physical footprint, so mechanical fit is identical. The difference is in the internal trip curve and accessories — verify the 8HM32-0AA0's trip characteristics against the 7MN32-0AG0's motor-protection curve before swapping.

What is 3VA2163-7MN32-0AG0's listed depth (86 mm) on this component line?

Depth is 86 mm (3.39 in), width 105 mm (4.13 in), height 181 mm (7.13 in). The 105 mm width occupies three 35 mm DIN-rail modules.

MPN
3VA2163-7MN32-0AG0