Siemens 3VA2163-7MN32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN32-0KA0 SENTRON MCCB, 63 A, 3-Pole, Shunt

MPN3VA2163-7MN32-0KA0

Siemens SENTRON 3VA2163-7MN32-0KA0, molded case circuit breaker, 3-pole, 63 A, 330 kA interrupting at 240 V, shunt trip release, motor protection design.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7MN32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN32-0AA0
3VA2163-7MN32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7MN32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7MN32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MN32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7MN32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MN32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-7MN32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current, flat across the entire operating temperature range from 40 °C to 70 °C — no derating needed as the panel warms up. The interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, and 187 kA at 500 V; at 690 V it drops to 3.7 kA, so keep that in mind for high-voltage feeders.

Panel fit and footprint

It measures 105 mm wide, 181 mm tall, and 86 mm deep — that's 4.13 by 7.13 by 3.39 inches. The shunt trip adds a pair of control wires; plan for a 24 VDC or 110-240 VAC signal depending on the release coil ordered. No auxiliary switch or undervoltage release on this variant, so if you need those, look at the 3VA2163-7MN32-0AA0 base switch or add an external accessory.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-7MN32-0KA0?

Submit an RFQ through this listing. We confirm pricing and stock at quote time from our independent distribution network.

When sourcing 3VA2163-7MN32-0KA0, what's the closest functional second-source?

The 3VA2116-5JP32-0AE0 is a lower-rated sibling in the same SENTRON 3VA family, but it carries different interrupting ratings and accessories. They share the same form factor, so a panel designed for one can accept the other without rewiring, as long as the current and interrupting requirements match.

What is 3VA2163-7MN32-0KA0's listed depth (86 mm) on this component line?

The depth is 86 mm (3.39 inches). That's the body depth behind the panel face, not including handle or terminal protrusions.

What is 3VA2163-7MN32-0KA0's listed width (105 mm) on this component line?

The width is 105 mm (4.13 inches). Three poles fit in that width — standard for a 3-pole MCCB in this frame size.

Will 3VA2163-7MN32-0KA0 drop into a panel that was specified around 3VA2116-5JP32-0AE0 without rewiring?

Yes, the physical dimensions are identical — same width, height, and depth — so it mounts in the same footprint. The terminal layout is also the same, so no busbar or cable rework is needed. Just verify that the 63 A rating and 330 kA interrupting capacity match your coordination study.

What compliance documentation does this brand provide for 3VA2163-7MN32-0KA0 (RoHS, REACH, UL, IEC)?

Siemens SENTRON MCCBs are designed to IEC 60947-2 and carry CE marking. RoHS and REACH declarations are standard from Siemens. UL listing depends on the specific variant; check the nameplate for UL/CSA marks. We can provide the manufacturer's declaration of conformity upon request.