Skip to main content
Siemens 3VA2163-7MN36-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-7MN36-0AC0 MCCB, 63 A, 3-pole, Motor

MPN3VA2163-7MN36-0AC0

Siemens SENTRON 3VA2163-7MN36-0AC0, molded case circuit breaker, 3-pole, 63 A, motor protection version with ETU350M electronic overcurrent release, 330 kA at 240 V SCCR.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MN36-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2163-7MN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-7MN36-0AC0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.75 W

Protection & Trip Unit

3VA2163-7MN36-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M

Construction & Connection

3VA2163-7MN36-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MN36-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-7MN36-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MN36-0AC0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens SENTRON 3VA2163-7MN36-0AC0 is a 3-pole molded case circuit breaker rated 63 A continuous current, built for motor protection duty. The ETU350M electronic overcurrent release provides adjustable thermal-magnetic curves with phase failure detection — so it catches a dropped phase on a three-phase motor load before the winding cooks. No undervoltage release, no ground-fault module, no communication stack: this is a standalone thermal-magnetic MCCB for a motor branch circuit, not a power-monitoring node. SCCR is the headline number here. At 240 V the breaker interrupts 330 kA; at 415 V and 440 V it holds 242 kA, and at 690 V it still clears 52.5 kA. Those are high-fault ratings — typical for a large-frame industrial MCCB installed at the service entrance or feeding a motor control center where available fault current exceeds 100 kA. The 63 A rating is flat from 40 °C through 50 °C, then derates to 60.48 A at 55 °C and 56.7 A at 70 °C. If the panel ambient runs above 50 °C, the continuous load stays under 57 A. Physical fit: 105 mm wide, 181 mm tall, 86 mm deep. Fixed mount — no DIN-rail clip on this frame size. The 2 auxiliary switches (HQ type) are pre-installed; the integrated auxiliary trip is order code 3VA9688-0BL33. Max power dissipation is 75 W, so the panel ventilation needs to move that heat. Latching endurance is 20 000 cycles — mechanical life is higher, but the latching mechanism is the wear item for frequent switching applications.

Frequently asked questions

What is the interrupting rating of 3VA2163-7MN36-0AC0 at 415 V?

At 415 V the SCCR is 242 kA, matching the rating at 440 V. At 240 V it reaches 330 kA, and at 690 V it clears 52.5 kA.

How do I get pricing and availability for 3VA2163-7MN36-0AC0?

The part is quoted to order against an RFQ. Availability and current pricing are confirmed at quote time through independent distribution channels.

Does 3VA2163-7MN36-0AC0 include phase failure detection?

Yes, the ETU350M release includes phase failure detection. It also carries 2 pre-installed HQ auxiliary switches but no undervoltage release, ground-fault module, or communication function.

What is the closest functional alternative to 3VA2163-7MN36-0AC0?

The Siemens 5SQ2370 series breakers (5SQ2370-2YA05, -2YA04, -2YA01) share the same 63 A, 3-pole form factor and motor protection class. The 3VA2163-7MN36-0AC0 uses the ETU350M electronic release with phase failure detection; the 5SQ2370 variants typically carry a different release family. Verify the trip curve and auxiliary count before substituting — the mounting footprint and terminal layout are compatible, but the release logic differs.

MPN
3VA2163-7MN36-0AC0