Specifications

Identification

3VA2163-7MN36-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-7MN36-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MN36-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MN36-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MN36-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-7MN36-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MN36-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-7MN36-0AD0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full operating temperature range from -25 °C to 70 °C, with no derating needed up to 70 °C. Its interrupting capacity reaches 330 kA at 240 V AC, stepping down to 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — the sharp drop at 690 V reflects the arc extinction limits of the 3-pole series-trip design, so verify the fault current at your system voltage before specifying.

Motor protection and internal configuration

This MCCB is explicitly designed for motor protection, which means the trip curve and thermal-magnetic response are tuned for the inrush and overload profile of induction motors, not for general distribution or resistive loads. Phase failure detection is built in, so a lost phase on the line side will trip the breaker before single-phasing damages the motor — a critical feature for unmonitored or remote motor circuits. The unit carries three high-quality auxiliary switches for status feedback to a PLC or annunciator panel, and the basic switch assembly is order code 3VA2163-7MN36-0AA0.

Mechanical footprint and panel fit

Dimensions are 105 mm wide, 181 mm high, and 86 mm deep — a standard SENTRON 3VA2 frame size. The 105 mm width occupies three 35 mm DIN-spaces (standard 17.5 mm per module), so it fits a conventional DIN-rail enclosure without overhang. Maximum power loss is 4 W, which keeps internal cabinet heating manageable; no forced ventilation needed for a single unit, but a multi-breaker panel should account for cumulative dissipation in the thermal budget.

Frequently asked questions

Where can I buy 3VA2163-7MN36-0AD0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote (RFQ) to confirm current availability and pricing.

What is 3VA2163-7MN36-0AD0's listed depth?

The listed depth is 86 mm.

What is the continuous current rating at elevated ambient temperatures?

The breaker holds 63 A continuously from 40 °C up through 70 °C — no derating is required across the entire operating range.

MPN