Siemens 3VA2163-7MN36-0BL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN36-0BL0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-7MN36-0BL0

Siemens SENTRON 3VA2163-7MN36-0BL0, molded case circuit breaker, 3-pole, 63 A, motor protection variant with ETU350M electronic trip unit, 330 kA breaking capacity at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7MN36-0BL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2163-7MN36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2163-7MN36-0BL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.6.5 W
3VA2163-7MN36-0BL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
3VA2163-7MN36-0BL0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MN36-0BL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2163-7MN36-0BL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MN36-0BL0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Motor Protection MCCB with Flat Derating to 70 °C

Breaking capacity is substantial: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V.

Panel Fit and Auxiliary Contact Configuration

The 105 mm width is standard for a 3-pole 63 A frame in the 3VA series — it occupies three 35 mm DIN module positions if panel-mounted, or bolts directly into a mounting plate. Depth of 86 mm leaves clearance behind the panel for wiring and the auxiliary contact block.

Protection and Release Features

Includes an undervoltage release and phase failure detection as standard — both critical for motor protection applications where a phase loss can single-phase a motor and cause winding damage.

Frequently asked questions

What is the breaking capacity of this MCCB at different voltages?

Breaking capacity is 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V.

Does this breaker require derating at high ambient temperatures?

No — it maintains its full 63 A rating from 40 °C through 70 °C, so no derating is needed up to the maximum operating ambient of 70 °C.

Where can I buy 3VA2163-7MN36-0BL0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2163-7MN36-0BL0