Siemens 3VA2163-7MN36-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MN36-0KA0 SENTRON MCCB, 63 A, 3-Pole, Motor

MPN3VA2163-7MN36-0KA0

Siemens SENTRON 3VA2 series, molded case circuit breaker (MCCB), 3VA2163-7MN36-0KA0, 3-pole, 63 A, motor protection design, shunt trip release, phase failure detection.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MN36-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MN36-0AA0

Ratings

3VA2163-7MN36-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MN36-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MN36-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MN36-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-7MN36-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MN36-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB is and what it does

The Siemens 3VA2163-7MN36-0KA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) designed for motor protection, carrying a full-load rating of 63 A across the entire ambient temperature range from 40 °C through 70 °C without derating. That flat thermal curve means the breaker holds its 63 A trip threshold even inside a hot panel near a motor starter — no need to oversize for a 50 °C or 60 °C cabinet. Three poles, shunt trip release fitted, phase failure detection built in. The 3-pole construction matches standard three-phase motor feeds; the shunt trip (STL) allows remote emergency-off or undervoltage tripping from a PLC or E-stop circuit.

Breaking capacity — what the numbers mean for panel coordination

Rated breaking capacity of 330 kA at 240 V AC, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. The 330 kA at 240 V is typical for high-fault industrial distribution panels where the transformer secondary can deliver massive short-circuit current; the 242 kA at 415 V covers most European 400 V three-phase systems. The steep drop to 3.7 kA at 690 V means this breaker is not intended for 690 V motor circuits — that figure is essentially a residual capability for control-power faults, not a working rating. For a 400 V line-up, the 242 kA SCCR gives generous headroom for selective coordination with downstream feeders.

Trip delay settings and motor protection logic

Adjustable short-time delay from 4 s minimum to 17 s maximum, allowing coordination with downstream branch breakers or motor starters during inrush. The motor protection design includes phase failure detection, which trips on loss of one phase — critical for preventing single-phasing damage on a three-phase motor. No ground-fault monitoring version fitted on this variant; if ground-fault protection is needed, the basic switch order code 3VA2163-7MN36-0AA0 is the base platform this breaker builds on.

Physical fit and panel integration

Dimensions: 105 mm wide, 181 mm high, 86 mm deep. The 105 mm width is a standard 3-pole MCCB footprint for this current class — fits the same panel cut-out and bus-bar spacing as other 3VA2 3-pole frames. Depth of 86 mm means it clears most 200 mm deep enclosures with room for rear bus connections. No auxiliary switch fitted on this order code; the shunt trip release is the only internal accessory. If you need an auxiliary contact for status feedback, that would be a separate add-on module.

Frequently asked questions

What is the breaking capacity of 3VA2163-7MN36-0KA0 at 415 V?

Rated breaking capacity is 242 kA at 415 V AC, suitable for high-fault 400 V three-phase industrial distribution.

Does this MCCB include phase failure protection?

Yes, phase failure detection is built in — it trips on loss of one phase to protect three-phase motors from single-phasing damage.

What is the rated current of 3VA2163-7MN36-0KA0?

Rated current is 63 A, and it holds that rating across the full ambient temperature range from 40 °C to 70 °C without derating.

Where can I buy 3VA2163-7MN36-0KA0 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commercial response.