Skip to main content
Siemens 3VA2163-7MP32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MP32-0AA0 SENTRON MCCB, 63A, 3-Pole, 330kA

MPN3VA2163-7MP32-0AA0
Active

Siemens SENTRON 3VA2163-7MP32-0AA0, molded case circuit breaker, 3-pole, 63 A, motor protection design, adjustable trip class 10A/10/20/30, 330 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MP32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON

Ratings

3VA2163-7MP32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MP32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MP32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MP32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2163-7MP32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MP32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for motor protection — 63 A, 3-pole, high interrupting capacity

The Siemens SENTRON 3VA2163-7MP32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed in a warm enclosure. Its motor protection design includes adjustable trip classes (10A, 10, 20, 30) and phase failure detection, so it can be tuned to the thermal time constant of the motor load. The interrupting capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V — that SCCR headroom lets it sit upstream of a high-fault panel without cascading coordination issues. Rated insulation voltage is 800 V. A communication function is built in for remote monitoring or trip-event capture.

Panel fit and integration

The 3VA2163-7MP32-0AA0 measures 105 mm wide, 181 mm high, and 86 mm deep. It mounts on a DIN rail or can be screw-fixed to a backplate. The 3-pole footprint is standard for a 63 A frame MCCB — expect it to occupy roughly 4 inches of DIN width. No undervoltage release or ground-fault module is integrated, so those functions would need external add-ons if required.

Frequently asked questions

What is 3VA2163-7MP32-0AA0's listed depth?

The listed depth is 86 mm (3.39 inches).

MPN
3VA2163-7MP32-0AA0