Specifications

3VA2163-7MS36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-7MS36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W
3VA2163-7MS36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-7MS36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MS36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-7MS36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MS36-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Interrupting capacity varies sharply by voltage: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, dropping to 3.7 kA at 690 V. The 3.7 kA figure at 690 V is the practical limit — this breaker is not intended for high-fault 690 V motor circuits. The trip current range spans 189 A minimum to 945 A maximum (3x to 15x the 63 A frame), which covers DOL motor starts up to about 30 kW without nuisance tripping.

Listed as current production (active lifecycle stage). No end-of-life notice or successor order code is available.

The 105 mm width (4.13 in) is a standard 3-pole MCCB footprint for a 160 A frame — it occupies the same DIN-rail or panel-mount cutout as other SENTRON 3VA2 devices.

Rated for operation from -25 °C to 70 °C ambient, with no derating required across the full 63 A load range from 40 °C through 70 °C. Maximum power loss is 4 W. Insulation voltage rated at 800 V. The SENTRON series carries UL, CSA, and IEC certifications; compliance documentation (RoHS, REACH) is provided with the unit.