Skip to main content
Siemens 3VA2163-7MS36-0AF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MS36-0AF0 SENTRON MCCB, 63 A, 3-pole, 242 k

MPN3VA2163-7MS36-0AF0

Siemens SENTRON molded case circuit breaker, 3VA2163-7MS36-0AF0, 3-pole, 63 A rated, 242 kA at 415 V, starter protection design with 1 auxiliary + 1 trip alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MS36-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MS36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-7MS36-0AF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MS36-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MS36-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MS36-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-7MS36-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MS36-0AF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-7MS36-0AF0 is a 3-pole molded case circuit breaker (MCCB) designed for starter protection, carrying a full-load current rating of 63 A across the entire 40 °C to 70 °C ambient range — no derating needed at elevated panel temperatures. Its interrupting capacity hits 242 kA at 415 V, which puts it in the high-fault class for industrial distribution: it clears a bolted fault upstream of a motor starter without the arc flash energy cascading to downstream contactors. The breaker ships with a factory-fitted 1 auxiliary switch plus 1 trip alarm switch HQ, so the panel builder gets both a position feedback contact and a separate fault-indicating contact without ordering add-on modules.

Breaking capacity across voltages

The 3VA2163-7MS36-0AF0 delivers 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 3.7 kA at 690 V. That steep drop at 690 V is the key constraint: on a 690 V line (common in mining or marine installations), the 3.7 kA rating limits the available fault current the breaker can safely interrupt — coordination studies must respect that ceiling.

Frequently asked questions

What is the breaking capacity of 3VA2163-7MS36-0AF0 at 415 V?

The interrupting rating is 242 kA at 415 V, covering most industrial service-entrance and distribution applications at that voltage level.

How do I get pricing and availability for 3VA2163-7MS36-0AF0?

This part is quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What auxiliary switches come fitted on 3VA2163-7MS36-0AF0?

It ships with 1 auxiliary switch and 1 trip alarm switch HQ, providing both a normal position signal and a separate fault-indicating contact.

MPN
3VA2163-7MS36-0AF0