Siemens 3VA2163-7MS36-0CH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MS36-0CH0 SENTRON MCCB, 63 A, 3-Pole, Start

MPN3VA2163-7MS36-0CH0

Siemens SENTRON 3VA2163-7MS36-0CH0, molded case circuit breaker, 3-pole, 63 A, starter protection variant, ETU310M electronic trip unit, with undervoltage release and HQ auxiliary switch pack.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2163-7MS36-0CH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionStarter protection
Basic switch (supplied) ref.3VA2163-7MS36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2163-7MS36-0CH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C60.48 A
Current at 60 °C59.22 A
Current at 65 °C57.96 A
Current at 70 °C56.7 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.75 W
3VA2163-7MS36-0CH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
3VA2163-7MS36-0CH0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-7MS36-0CH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2163-7MS36-0CH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-7MS36-0CH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this 3VA2 is — and what it isn't

Rated continuous current Iu is 63 A, and it holds that rating from 40 °C up through 50 °C without derating; at 55 °C it's still at 60.48 A, and at 70 °C it's 56.7 A, so the thermal headroom is generous for a 63 A frame. The ETU310M electronic trip unit handles the overcurrent release, and there's an undervoltage release (UVR) integrated — the auxiliary release design is UVR, and the supplied basic switch is order code 3VA2163-7MS36-0AA0 with an integrated auxiliary trip of 3VA9608-0BB24. No communication function, no phase failure detection, no ground fault monitoring — this is a straightforward motor-protection MCCB, not a networked power monitor.

SCCR — what the interrupting ratings mean for panel coordination

The interrupting capacity is given across five voltage points, which is what you need for selectivity studies. At 240 V it's 330 kA; at 415 V and 440 V it's 242 kA; at 500 V it's 187 kA; at 690 V it's 52.5 kA.

Mechanical endurance is 20,000 operations — adequate for motor starting duty where the breaker isn't cycled daily as a disconnect.

Frequently asked questions

How do I get current pricing and availability for 3VA2163-7MS36-0CH0?

We source this part to order against an RFQ. Submit a request and we'll confirm current pricing and lead time at quote time.

Will 3VA2163-7MS36-0CH0 drop into a panel specified around 3VA2163-8HM32-0AA0?

The physical footprint is the same 3VA2 frame, so it will mount in the same DIN rail or backplate position. However, verify the auxiliary contact wiring (2 aux + 1 trip alarm vs the 8HM32's configuration) and the presence of the undervoltage release — the UVR coil wiring is additional and may require a different terminal assignment.

MPN
3VA2163-7MS36-0CH0