Skip to main content
Siemens 3VA2163-7MS36-0JC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-7MS36-0JC0 SENTRON MCCB, 63 A, 3-Pole, 330 k

MPN3VA2163-7MS36-0JC0

Siemens SENTRON 3VA2163-7MS36-0JC0, Molded case circuit breaker, 3-pole, 63 A, 330 kA at 240 V, starter protection design with shunt trip release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MS36-0JC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MS36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12

Ratings

3VA2163-7MS36-0JC0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MS36-0JC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MS36-0JC0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MS36-0JC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2163-7MS36-0JC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MS36-0JC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

MCCB for Motor and Starter Protection

The Siemens SENTRON 3VA2163-7MS36-0JC0 is a 3-pole molded case circuit breaker (MCCB) rated at 63 A continuous current across the full ambient range from 40 °C to 70 °C, meaning no derating is needed for elevated panel temperatures up to that limit. Its interrupting capacity hits 330 kA at 240 V and 242 kA at 415 V, so it can clear high-fault currents on industrial distribution without cascading upstream breakers. The design is explicitly for starter protection, which means it's tuned for motor-starting inrush and coordinated with contactor/overload combinations in a motor control center.

Integrated Shunt Trip and Auxiliary Switching

This variant comes factory-fitted with a shunt trip release (STL) for remote tripping via a control signal, plus two high-capacity auxiliary switches (HQ) for status feedback to a PLC or annunciator panel. The auxiliary switches share the same compact frame, so no external relay interface is needed for remote indication. The shunt trip allows emergency-stop circuits or supervisory systems to open the breaker without a manual action.

Panel Fit and Mounting

The breaker measures 105 mm wide, 181 mm tall, and 86 mm deep, fitting standard Siemens SENTRON 3VA panel cutouts and busbar systems. It mounts via screw terminals on the line and load sides, with a depth that clears most 200 mm deep enclosures. The 3-pole footprint matches the typical MCC bucket layout for motor feeder groups.

Frequently asked questions

What are the key ratings for this MCCB?

It is a 3-pole, 63 A molded case circuit breaker with a 330 kA interrupting capacity at 240 V and 242 kA at 415 V, designed for starter protection.

What is the interrupting capacity at 690 V?

At 690 V the interrupting capacity is 3.7 kA, which is typical for this frame size at higher voltages.

Does this breaker include a shunt trip?

Yes, it is fitted with a shunt trip release (STL) for remote tripping, plus two high-capacity auxiliary switches (HQ) for status feedback.

Where can I buy 3VA2163-7MS36-0JC0?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN