Siemens 3VA2163-7MS36-0KH0 SENTRON MCCB, 63 A, 3-Pole, 330 k

MPN3VA2163-7MS36-0KH0

Siemens SENTRON 3VA2163-7MS36-0KH0, molded case circuit breaker, 3-pole, 63 A rated at 40 °C, 330 kA breaking capacity at 240 V, starter protection design with shunt trip and auxiliary switches.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2163-7MS36-0KH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2163-7MS36-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2163-7MS36-0KH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.4 W

Protection & Trip Unit

3VA2163-7MS36-0KH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU310M
Overcurrent protection functionI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2163-7MS36-0KH0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2163-7MS36-0KH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2163-7MS36-0KH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2163-7MS36-0KH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2163-7MS36-0KH0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous at 40 °C ambient, with a thermal-magnetic trip unit adjustable from 189 A minimum to 945 A maximum — sized for motor and starter protection in industrial control panels. Its interrupting capacity hits 330 kA at 240 V AC and still holds 242 kA at 415 V and 440 V, dropping to 187 kA at 500 V and 3.7 kA at 690 V — that SCCR headroom means it clears high-fault bolted faults without cascading upstream, critical for panel selectivity studies. The breaker carries a shunt trip release (STL) and is factory-equipped with 2 auxiliary switches plus 1 trip alarm switch (HQ configuration), giving the controls integrator direct feedback into the PLC or safety relay without external interface modules.

Lifecycle and Sourcing Reality

For compliance documentation, Siemens provides the standard SENTRON declaration pack: CE marking per Low Voltage Directive 2014/35/EU, UL 489 listing, CSA C22.2 No. 5, and IEC 60947-2. RoHS and REACH declarations are available on request.

Integration and Mounting

The 3VA2163-7MS36-0KH0 occupies 105 mm width, 181 mm height, and 86 mm depth — a standard SENTRON 3VA frame footprint that drops into existing MCCB panel cutouts without rewiring if the panel was specified for the same frame family. It is designed for fixed mounting on a mounting plate or DIN rail adapter (not included), with tunnel-type terminals accepting copper or aluminum conductors. The 63 A rating is maintained across the full -25 °C to 70 °C operating range — no derating curve to manage in warm enclosures.

Selectivity and Coordination

With a trip indicator and voltage trigger (shunt release), this MCCB supports zone-selective interlocking (ZSI) when paired with a compatible upstream breaker — the 330 kA IC at 240 V ensures full discrimination down to the 189 A minimum trip setting, holding the arc energy inside the breaker rather than letting it propagate to the busbar.

Frequently asked questions

What is the closest functional second-source for 3VA2163-7MS36-0KH0?

The 3VA2163-8HM32-0AA0 is a functional peer within the same SENTRON 3VA frame family, sharing the same 3-pole, 63 A thermal-magnetic trip and similar breaking capacities. The main difference is the auxiliary switch configuration and release options — verify the specific wiring diagram before substitution.

How do I get current pricing and availability for 3VA2163-7MS36-0KH0?

Submit an RFQ through the storefront. Availability and current pricing are confirmed at quote time through our independent distribution network.

Will 3VA2163-7MS36-0KH0 drop into a panel specified around 3VA2163-8HM32-0AA0 without rewiring?

Yes, both breakers share the same SENTRON 3VA frame dimensions (105 mm width, 181 mm height, 86 mm depth) and terminal layout, so physical replacement is a direct swap. However, the auxiliary switch count differs — the -7MS36 carries 2 aux + 1 trip alarm, while the -8HM32 may have a different configuration — so check the control wiring against the new breaker's terminal assignments.

What compliance documentation does this brand provide for 3VA2163-7MS36-0KH0?

Siemens provides CE marking (2014/35/EU), UL 489 listing, CSA C22.2 No. 5, and IEC 60947-2 compliance. RoHS and REACH declarations are available on request from the manufacturer.