Siemens 3VA2163-8HN32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2163-8HN32-0AA0 MCCB, 63 A, 440 kA at 240

MPN3VA2163-8HN32-0AA0
Active

Siemens SENTRON 3VA2163-8HN32-0AA0, molded case circuit breaker, 3-pole, 63 A continuous, ETU350 electronic trip unit, 440 kA breaking capacity at 240 V AC, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-8HN32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2163-8HN32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classL
Breaking capacity at 240 V440 kA
Breaking capacity at 415 V330 kA
Breaking capacity at 440 V330 kA
Breaking capacity at 500 V220 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.3.1 W
3VA2163-8HN32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2163-8HN32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-8HN32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-8HN32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-8HN32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2163-8HN32-0AA0 — 63 A MCCB with ETU350 Trip Unit

The Siemens SENTRON 3VA2163-8HN32-0AA0 is a 3-pole molded case circuit breaker (MCCB) rated for 63 A continuous current across the full 40 °C to 70 °C ambient range — no derating needed as the panel warms up. It carries a 440 kA interrupting capacity at 240 V AC, dropping to 330 kA at 415 V and 440 V, 220 kA at 500 V, and 52.5 kA at 690 V. Panel integration is straightforward: the 105 mm width fits standard Siemens SENTRON mounting patterns, and the 181 mm height with 86 mm depth leaves room for cable bending radius in a typical 600 mm deep enclosure. Power loss is a modest 3.1 W maximum, so heat buildup in a dense lineup is manageable.

Peer Comparison — 3VA2163-8HM32-0AA0

The closest functional sibling is the 3VA2163-8HM32-0AA0. Both are 3-pole, 63 A, SENTRON MCCBs with the same frame size and interrupting ratings. The difference is the trip unit: the -8HN32 carries the ETU350 (electronic, adjustable), while the -8HM32 uses a thermal-magnetic trip. If your coordination study calls for electronic selectivity or adjustable short-time delay, the -8HN32 is the correct choice. If the panel was specified around the -8HM32, the -8HN32 drops into the same mounting footprint and bus connections without rewiring — just verify the trip curve matches your protective device coordination.

Frequently asked questions

Will 3VA2163-8HN32-0AA0 fit in a panel designed for 3VA2163-8HM32-0AA0?

Yes — same frame size, same 105 mm width, 181 mm height, 86 mm depth. The mounting footprint and bus connections are identical. The only difference is the trip unit (ETU350 electronic vs. thermal-magnetic), so verify coordination before swapping.

MPN
3VA2163-8HN32-0AA0