Siemens 3VA2216-5HL32-0DH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-5HL32-0DH0 SENTRON MCCB, 160 A, 3-Pole, 187

MPN3VA2216-5HL32-0DH0

Siemens SENTRON 3VA2216-5HL32-0DH0, molded case circuit breaker, 3-pole, 160 A rated continuous current, 187 kA interrupting at 240 V, line protection, ETU320 release, undervoltage release, 2 aux + 1 alarm switch.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2216-5HL32-0DH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2216-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA2216-5HL32-0DH0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C154 A
Current at 60 °C148 A
Current at 65 °C142 A
Current at 70 °C136 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V79 kA
Breaking capacity at 690 V5.1 kA
Power loss, max.22.2 W
3VA2216-5HL32-0DH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2216-5HL32-0DH0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-5HL32-0DH0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2216-5HL32-0DH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-5HL32-0DH0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

The Siemens 3VA2216-5HL32-0DH0 is a 3-pole SENTRON molded case circuit breaker rated for 160 A continuous current at 40 °C, with an interrupting capacity of 187 kA at 240 V. That 187 kA figure drops to 121 kA at 415 V and 440 V, then to 79 kA at 500 V, and finally to 5.1 kA at 690 V — the SCCR curve tells you where this breaker has real fault-clearing headroom and where it doesn't.

Thermal derating — the real continuous rating at your panel temp

At 55 °C it derates to 154 A, at 60 °C to 148 A, at 65 °C to 142 A, and at 70 °C to 136 A. If your panel ambient runs 65 °C, you're sizing for 142 A continuous, not 160 A.

Physical fit — panel cutout and mounting

The undervoltage release and ETU320 are factory-integrated, so no field-kit assembly needed.

Frequently asked questions

What is the interrupting capacity of 3VA2216-5HL32-0DH0 at 415 V?

121 kA at 415 V, same as at 440 V. At 500 V it drops to 79 kA, and at 690 V to 5.1 kA.

Where can I buy 3VA2216-5HL32-0DH0?

This MCCB is available to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What does the auxiliary contact configuration include?

2 auxiliary switches plus 1 trip alarm switch (HQ type). That gives you separate signaling for breaker open/closed and for fault-trip events.