Siemens 3VA2216-5HL32-0JH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-5HL32-0JH0 SENTRON MCCB, 160 A, 3-Pole, 1920

MPN3VA2216-5HL32-0JH0

Siemens SENTRON 3VA2216-5HL32-0JH0, 3-pole molded case circuit breaker, 160 A continuous, adjustable 240–1920 A, 187 kA at 240 V.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-5HL32-0JH0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2216-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2216-5HL32-0JH0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-5HL32-0JH0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2216-5HL32-0JH0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-5HL32-0JH0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3

Environmental

3VA2216-5HL32-0JH0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-5HL32-0JH0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens SENTRON 3VA2216-5HL32-0JH0 — 160 A Molded Case Circuit Breaker

The Siemens SENTRON 3VA2216-5HL32-0JH0 is a 3-pole molded case circuit breaker (MCCB) rated for 160 A continuous current, with an adjustable overload trip range from 240 A to 1920 A. It's designed for line protection in distribution panels and motor control centers, where you need selective coordination and high fault current handling. Breaking capacity is substantial: 187 kA at 240 V, 121 kA at 415 V and 440 V, dropping to 75.6 kA at 500 V, and 4.5 kA at 690 V. That 187 kA figure at 240 V means it can safely clear a massive fault without rupturing — critical for high-capacity transformer secondaries or busway feeds where available fault current is high. Continuous current holds at 160 A across the full operating temperature range from -25 °C to 70 °C, so you don't lose capacity in a hot panel. The shunt trip (STL) release lets you remotely trip the breaker via a control signal — useful for emergency stops or interlocking schemes. Auxiliary contacts include two auxiliary switches plus one trip alarm switch (HQ configuration), giving you status feedback for PLC inputs or annunciator panels. The trip indicator and voltage trigger are present; undervoltage release and ground-fault monitoring are not fitted on this variant.

Dimensions and Panel Fit

Physical footprint: 105 mm wide, 181 mm tall, 86 mm deep. That 105 mm width is standard for a 3-pole MCCB in this frame size — it fits the usual DIN-rail or panel-mount cutout without surprises. Depth of 86 mm means it clears most standard enclosure backplates, but check your gland plate clearance if the breaker sits near the rear wall. Maximum power loss is 19.7 W, so factor that into your enclosure thermal budget — especially if multiple breakers are ganged in a sealed cabinet.

Frequently asked questions

What is the continuous current rating of this breaker?

160 A continuous, and it holds that rating across the full operating temperature range from -25 °C to 70 °C without derating.

Does this breaker include a shunt trip?

Yes, it has a shunt trip (STL) release for remote tripping via a control signal. It also includes two auxiliary switches and one trip alarm switch for status feedback.