Skip to main content
Siemens 3VA2216-5HN32-0AH0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-5HN32-0AH0 Circuit Breaker, 55kA @ 415V, 160

MPN3VA2216-5HN32-0AH0

Siemens 3VA2 IEC frame 250 MCCB, breaking capacity class M, Icu=55kA @ 415V, 3-pole, ETU350 LSI trip unit, In=160A, Ir=63A...160A, Isd=1.5...10 x Ir, Ii=12 x In, with 2 auxiliary switches and 1 trip alarm switch.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Product details

What this 3VA2 breaker brings to the panel

The Siemens 3VA2216-5HN32-0AH0 is a 3-pole IEC molded-case circuit breaker on the 250 A frame, fitted with an ETU350 LSI electronic trip unit. It is rated for line protection with a 55 kA interrupting capacity at 415 V (breaking capacity class M), which means it can safely clear fault currents up to that level in a 415 VAC system without the arc flashing over to adjacent equipment. This SCCR headroom is what lets you coordinate it downstream of a higher-rated main breaker and still meet the short-circuit rating required by IEC 60947-2. The continuous current rating (In) is 160 A, with the overload protection (Ir) adjustable from 63 A to 160 A. Short-circuit protection (Isd) is set between 1.5 and 10 times Ir, and the instantaneous pickup (Ii) is fixed at 12 times In. That LSI curve — long-time, short-time, instantaneous — gives the selectivity needed to coordinate with downstream branch breakers and avoid nuisance tripping on motor-start inrush or transformer energization. Two auxiliary switches (changeover H) and one trip alarm switch (changeover) are factory-fitted, so you get remote status indication and a separate alarm contact for fault annunciation without adding accessory modules. The nut keeper kit is included, which simplifies panel mounting on a DIN rail or backplate.

Deployment context: where this breaker fits

This MCCB is sized for a 160 A feeder or large motor branch in a 415 V industrial panel. The 55 kA breaking capacity at 415 V is typical for secondary distribution in a facility with a medium-voltage transformer — it handles the available fault current without needing a current-limiting upstream device. The 3-pole format suits three-phase loads: pumps, compressors, conveyors, or a distribution sub-panel. The ETU350's LSI curve lets you set short-time delay for selectivity with downstream breakers, which is critical in a multi-level distribution scheme.

Frequently asked questions

Where can I buy 3VA2216-5HN32-0AH0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the 3VA2216-5HN32-0AH0?

It is a 3-pole MCCB on the 250 A frame with a 55 kA interrupting capacity at 415 V, 160 A continuous rating (In), and an ETU350 LSI electronic trip unit with adjustable Ir (63 A to 160 A) and Isd (1.5 to 10 x Ir), plus a fixed Ii of 12 x In.

MPN
3VA2216-5HN32-0AH0