Siemens 3VA2216-5HR32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-5HR32-0AA0 MCCB, 160 A, 3-Pole, ETU345, 187

MPN3VA2216-5HR32-0AA0

Siemens 3VA2 series, molded case circuit breaker, 3VA2216-5HR32-0AA0, 160 A, 3-pole, ETU345 electronic trip unit, switching capacity class M, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Ratings

3VA2216-5HR32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V76 kA
Breaking capacity at 690 V17 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-5HR32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU345
Overcurrent protection functionLI DTVE
Ground-fault monitoringWithout

Construction & Connection

3VA2216-5HR32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-5HR32-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2216-5HR32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-5HR32-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.1 in
Width (in)4.1 in
Depth (in)3.4 in

Product details

What it is and what it does

The Siemens 3VA2216-5HR32-0AA0 is a 3-pole molded case circuit breaker (MCCB) from the 3VA2 series, rated 160 A continuous across the full ambient range of 40 °C to 70 °C — no derating needed up to that ceiling. The ETU345 electronic trip unit provides LI (long-time and instantaneous) protection with DTVE (earth-fault) capability, per the protection function designation LI DTVE. Switching capacity class M means this breaker handles high fault currents: 187 kA at 240 V AC, 121 kA at 415 V and 440 V, 76 kA at 500 V, and 17 kA at 690 V. The rated insulation voltage is 800 V, and the operating voltage goes to 690 V AC. For a panel-builder, that 187 kA at 240 V is the figure that decides whether this breaker clears a fault without upstream coordination — it's not a number you see on every MCCB.

Mounting and integration

Dimensions are 86 mm deep, 105 mm wide, 181 mm tall — fits standard panel cutouts for a 3-pole MCCB in this class. Electrical connection on both sides uses a nut keeper kit (supplied), so no loose hardware during assembly. The IP40 rating on the front means it's protected against tools and wires >1 mm, but not against water ingress; keep it inside a sealed enclosure for washdown environments. Power loss is 19.7 W maximum at rated current — a figure to factor into enclosure thermal calculations if the panel is densely packed. Mechanical service life is 20 000 switching cycles typical, which is standard for a distribution breaker; not intended for frequent motor starting.

Frequently asked questions

What trip unit does this breaker use?

The ETU345 electronic trip unit with LI DTVE protection — long-time and instantaneous overcurrent plus earth-fault detection.

MPN
3VA2216-5HR32-0AA0