Skip to main content
Siemens 3VA2216-5MN32-0KA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-5MN32-0KA0 SENTRON MCCB, 160 A, 3-Pole, Moto

MPN3VA2216-5MN32-0KA0

Siemens SENTRON 3VA2216-5MN32-0KA0, molded case circuit breaker, motor protection, 3-pole, 160 A at 40 °C, with shunt trip release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-5MN32-0KA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2216-5MN32-0AA0
3VA2216-5MN32-0KA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-5MN32-0KA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2216-5MN32-0KA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-5MN32-0KA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-5MN32-0KA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-5MN32-0KA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB does on the line

The Siemens SENTRON 3VA2216-5MN32-0KA0 is a 3-pole molded case circuit breaker (MCCB) rated for motor protection, carrying 160 A continuously from 40 °C up to 70 °C without derating — so it holds its full rating even in a warm panel, which is rare for a frame this size. Its interrupting capacity hits 187 kA at 240 V and still delivers 121 kA at 415 V, meaning it can clear a high-fault bolted short on a 400 V distribution bus without upstream fuses needing to open first — selectivity headroom for the engineer coordinating the panel. The built-in shunt trip (STL) release lets a remote PLC or E-stop pushbutton drop the breaker instantly, and the phase-failure detection trips on a lost phase before the motor single-phases and cooks the winding.

Maximum power loss is 19.7 W, so ventilation around the breaker in a sealed enclosure is advisable but not critical for most 160 A motor circuits.

Frequently asked questions

Where can I buy 3VA2216-5MN32-0KA0 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Submit a request for quote; availability and current pricing are confirmed at that time.

What is 3VA2216-5MN32-0KA0's interrupting capacity at 415 V?

It is rated 121 kA at 415 V, which covers most industrial 400 V distribution bus faults without requiring upstream current-limiting fuses.

Will 3VA2216-5MN32-0KA0 drop into a panel specified around 3VA2116-5JP32-0AE0 without rewiring?

Both are SENTRON 3VA frame breakers with the same 105 mm width and 86 mm depth, so the mechanical footprint and bus-bar centers match. The 3VA2216 carries 160 A versus the 3VA2116's lower rating, so verify the load-side conductor ampacity — the breaker itself will bolt in.

MPN
3VA2216-5MN32-0KA0