Skip to main content
Siemens 3VA2216-6HK42-0KC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-6HK42-0KC0 SENTRON MCCB, 160 A, 4-Pole, ETU3

MPN3VA2216-6HK42-0KC0

Siemens SENTRON 3VA2216-6HK42-0KC0, molded case circuit breaker, 4-pole, 160 A, ETU340 electronic trip unit, line protection, IP40 front.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-6HK42-0KC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2216-6HK42-0KC0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V42 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-6HK42-0KC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340

Construction & Connection

3VA2216-6HK42-0KC0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-6HK42-0KC0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes

Environmental

3VA2216-6HK42-0KC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-6HK42-0KC0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in

Product details

What this MCCB carries

The Siemens SENTRON 3VA2216-6HK42-0KC0 is a 4-pole molded case circuit breaker rated for 160 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. That 160 A holds steady at every temperature step in between, so you don't have to oversize for a warm panel. Its interrupting ratings climb to 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, and 42 kA at 690 V. Those numbers tell you this breaker can clear a bolted fault on a high-capacity transformer secondary without the arc flashing upstream — selectivity headroom for a main or feeder position. The ETU340 electronic trip unit handles the protection curve. Neutral protection is adjustable OFF, 50%, or 100% of the phase current. Latching endurance is rated at 20,000 operations.

Panel fit and integration

The case measures 140 mm wide, 181 mm high, and 86 mm deep. That 86 mm depth is the dimension that matters when you're laying out a shallow backpanel or a gland-plate clearance — it's the projection behind the door. The 140 mm width for a 4-pole frame tells you the pole spacing; verify your busbar or lug kit matches the SENTRON 3VA footprint before you drill. Front face protection is IP40 — suitable for a dry indoor panel, not for washdown areas. An optional motor drive can be added for remote switching, and the unit accepts communication modules if you need to tie it into a higher-level monitoring system.

Frequently asked questions

What is the depth of the 3VA2216-6HK42-0KC0?

86 mm — the dimension behind the panel door that governs gland-plate clearance and shallow-enclosure fit.

MPN
3VA2216-6HK42-0KC0