Skip to main content
Siemens 3VA2216-6HM42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-6HM42-0AA0 SENTRON MCCB, 160 A, 4-Pole, ETU3

MPN3VA2216-6HM42-0AA0
Active

Siemens SENTRON 3VA2216-6HM42-0AA0, molded case circuit breaker, 4-pole, 160 A, ETU330 electronic trip unit, breaking capacity 242 kA at 240 V AC.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-6HM42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2216-6HM42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-6HM42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2216-6HM42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-6HM42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-6HM42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-6HM42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

Line protection breaker with ETU330 — 160 A continuous, 4-pole

The Siemens SENTRON 3VA2216-6HM42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying 160 A continuous at 40 °C through 70 °C with no derating — a flat thermal curve that simplifies panel sizing in warm environments. Breaking capacity hits 242 kA at 240 V AC, 187 kA at 415 V and 440 V, and 121 kA at 500 V; at 690 V it still clears 4.5 kA, covering most industrial distribution fault levels. The ETU330 electronic trip unit provides adjustable I²t and instantaneous protection, plus N-conductor protection configurable to OFF, 50%, or 100% of the phase rating — useful for mixed-load panels where neutral sizing varies.

Panel fit and thermal management

Maximum power dissipation is 19.7 W at rated load; account for this in sealed enclosures to keep internal ambient below 70 °C operating max.

Frequently asked questions

What trip unit does the 3VA2216-6HM42-0AA0 use?

It uses the ETU330 electronic trip unit with adjustable I²t and instantaneous protection, plus configurable N-conductor protection (OFF, 50%, 100%).

MPN
3VA2216-6HM42-0AA0