Siemens 3VA2216-6JP32-0HF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-6JP32-0HF0 SENTRON MCCB, 160 A, 3-Pole, 242

MPN3VA2216-6JP32-0HF0

Siemens SENTRON 3VA2216-6JP32-0HF0, molded case circuit breaker, 3-pole, 160 A, 242 kA interrupting at 240 V, line protection design.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-6JP32-0HF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2216-6JP32-0HF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-6JP32-0HF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2216-6JP32-0HF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-6JP32-0HF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2216-6JP32-0HF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-6JP32-0HF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Siemens 3VA2216-6JP32-0HF0 SENTRON MCCB — 160 A, 3-Pole, Line Protection

This SENTRON 3VA2216-6JP32-0HF0 is a 3-pole molded case circuit breaker rated for 160 A continuous current at 40 °C, with a maximum interrupting capacity of 242 kA at 240 V — enough to handle high-fault utility feeds or transformer secondaries without cascading upstream. It's a line-protection design (not motor or generator protection), so the trip curve and accessories are tuned for feeder and main breaker duty in distribution panels. The breaker carries a shunt trip release (STL) and one auxiliary switch plus one trip alarm switch as standard, which means you can integrate remote tripping and status feedback without adding external relay logic. The communication function is onboard, so it can talk to a BMS or PLC for load shedding or event logging.

Breaking capacity across voltages — where it fits

At 415 V and 440 V it still delivers 187 kA, dropping to 121 kA at 500 V and 4.5 kA at 690 V. That last figure is the real boundary: if your panel runs 690 V with fault current above 4.5 kA, this breaker is not the right choice — you'd need a higher-rated frame. For 240–500 V systems, though, the margins are generous even for high-fault scenarios like large transformer banks or industrial substations.

Mounting and integration notes

The breaker measures 105 mm wide × 181 mm high × 86 mm deep — a standard MCCB footprint for 160 A frames. It mounts on a DIN rail or directly to a backplate via the integral lugs. The 86 mm depth means it fits into shallow enclosures where a deeper breaker would force a larger cabinet. Three poles, so it handles three-phase feeders; the neutral is not switched through this unit.

Environmental and thermal derating

Rated 160 A continuous across the full ambient range from 40 °C up to 70 °C — no derating needed until you exceed 70 °C, which is unusual for a 160 A frame. Storage range is -40 °C to 80 °C, operating -25 °C to 70 °C. Max power loss is 19.7 W, so heat dissipation inside the enclosure is modest for this current class.

Frequently asked questions

What is the interrupting capacity of 3VA2216-6JP32-0HF0 at 240 V?

242 kA at 240 V. At 415 V and 440 V it's 187 kA, at 500 V it's 121 kA, and at 690 V it's 4.5 kA.

What are the physical dimensions of 3VA2216-6JP32-0HF0?

105 mm wide, 181 mm high, 86 mm deep.

Where can I buy 3VA2216-6JP32-0HF0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time.