Skip to main content
Siemens 3VA2216-6JP32-0KF0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-6JP32-0KF0 MCCB, 160 A, 242 kA at 240 V

MPN3VA2216-6JP32-0KF0

Siemens SENTRON 3VA2216-6JP32-0KF0, 3-pole molded case circuit breaker, line protection, 160 A continuous, 242 kA breaking at 240 V, 86 x 105 x 181 mm.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-6JP32-0KF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.#BEZUG!
Integrated auxiliary / alarm switch ref.3VA9988-0AB12

Ratings

3VA2216-6JP32-0KF0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classH
Breaking capacity at 240 V242 kA
Breaking capacity at 415 V187 kA
Breaking capacity at 440 V187 kA
Breaking capacity at 500 V121 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-6JP32-0KF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU550
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo

Construction & Connection

3VA2216-6JP32-0KF0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-6JP32-0KF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerYes
Trip indicatorYes
Communication functionYes
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2216-6JP32-0KF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-6JP32-0KF0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB delivers

The Siemens SENTRON 3VA2216-6JP32-0KF0 is a 3-pole molded case circuit breaker rated 160 A continuous from 40 °C to 70 °C — no derating across that band, which simplifies panel design in warm enclosures. Breaking capacity hits 242 kA at 240 V and 187 kA at 415 V, so it handles high-fault utility feeds without cascading upstream breakers — a real advantage for main or tie applications where SCCR headroom is tight. Rated minimum 240 A and maximum 1 920 A define the magnetic trip range; the unit ships with a shunt trip release (STL) and one auxiliary switch plus one trip alarm switch HQ, giving the panel builder remote status and emergency trip without adding external relays. Communication function is built in, supporting integration with higher-level monitoring — no separate comm module needed.

Panel fit and environment

Measures 86 mm deep, 105 mm wide, 181 mm tall — a compact footprint for a 160 A MCCB, fitting standard distribution panel cutouts without special adapters. Operating range from -25 °C to 70 °C; storage from -40 °C to 80 °C. Maximum power loss 19.7 W — thermal management straightforward in a ventilated enclosure.

Key specs at a glance

Trip indicator and voltage trigger are standard. No undervoltage release, no ground-fault monitoring — those functions must be added externally if needed. Breaking capacities: 242 kA at 240 V, 187 kA at 415 V and 440 V, 121 kA at 500 V, 4.5 kA at 690 V. The steep drop at 690 V means this breaker is best applied on 400 V class systems for full fault-clearing performance.

Frequently asked questions

Does 3VA2216-6JP32-0KF0 include a shunt trip?

Yes, it ships with a shunt trip release (STL) plus one auxiliary switch and one trip alarm switch HQ.

MPN
3VA2216-6JP32-0KF0