Siemens 3VA2216-7HK42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7HK42-0AA0 SENTRON MCCB, 160 A, 4-Pole, ETU3

MPN3VA2216-7HK42-0AA0
Active

Siemens SENTRON 3VA2 molded case circuit breaker, 4-pole, 160 A, ETU340 electronic trip unit, line protection version, IP40 front, 690 V AC operating voltage.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-7HK42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection

Ratings

3VA2216-7HK42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W

Protection & Trip Unit

3VA2216-7HK42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU340
Overcurrent protection functionELISA LI
Ground-fault monitoringWithout

Construction & Connection

3VA2216-7HK42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-7HK42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0

Environmental

3VA2216-7HK42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-7HK42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

What this 4-pole 160 A MCCB delivers

The Siemens 3VA2216-7HK42-0AA0 is a SENTRON 3VA2 molded case circuit breaker (MCCB) configured for line protection in a 4-pole package. It carries a continuous current rating Iu of 160 A across the full ambient range from 40 °C to 70 °C — no derating needed up to the top of the operating band. The ETU340 electronic trip unit handles the overcurrent release, giving adjustable N-conductor protection (OFF, 50%, or 100% of phase current). Rated insulation voltage Ui is 800 V, and the breaker is rated for 690 V AC operating voltage. Short-circuit breaking capacity reaches 330 kA at 240 V AC, 242 kA at 415/440 V, 187 kA at 500 V, and 4.5 kA at 690 V. That 330 kA figure at 240 V means this MCCB can interrupt very high fault currents at the secondary side of a step-down transformer — a common requirement in industrial distribution panels feeding high-availability loads.

Panel integration and mounting

Dimensions are 86 mm deep, 140 mm wide, 181 mm high. The 140 mm width for a 4-pole frame is standard for SENTRON 3VA2 breakers — it matches the cutout and busbar spacing used across the series. Front protection is IP40, sufficient for enclosed panel mounting where the breaker face is behind a door or cover. Maximum power loss is 19.7 W. In a densely packed panel, that heat needs to be considered in the thermal budget — especially if multiple breakers are ganged without spacing.

Frequently asked questions

What trip unit does this MCCB use?

The ETU340 electronic overcurrent release, with adjustable N-conductor protection settings (OFF, 50%, 100%).

MPN
3VA2216-7HK42-0AA0