Skip to main content
Siemens 3VA2216-7HL32-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7HL32-0AA0 SENTRON MCCB, 160 A, 3-Pole, 330

MPN3VA2216-7HL32-0AA0
Active

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2216-7HL32-0AA0, 160 A rated current, 3-pole, ETU320 electronic trip unit, 330 kA breaking capacity at 240 V.

$533.40Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-7HL32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2216-7HL32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-7HL32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2216-7HL32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-7HL32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-7HL32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-7HL32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

160 A MCCB with flat thermal derating and high interrupting capacity

The Siemens 3VA2216-7HL32-0AA0 is a 3-pole SENTRON molded case circuit breaker rated for 160 A continuous current, carrying a full 160 A from 40 °C through 70 °C ambient — no derating needed across that span, which simplifies panel thermal budgeting for a line-protection install. Breaking capacity reaches 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V — the 690 V figure is the weak leg, so verify the available fault current at that voltage if the circuit runs above 500 V. Front IP40 protection suits panel-mount environments; the 86 mm depth, 105 mm width, and 181 mm height fit standard SENTRON 3VA2 cutout patterns, so a panel originally laid out for a 3VA2 frame accepts this unit without rework.

Three-pole design with no trip indicator and no undervoltage release — the auxiliary contact options are external, so if the BOM calls for a shunt trip or alarm contact, order those as separate accessories.

Frequently asked questions

What is the breaking capacity of 3VA2216-7HL32-0AA0 at different voltages?

330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V. The 690 V figure is the limiting value — confirm available fault current at that voltage before specifying.

Does 3VA2216-7HL32-0AA0 require derating at elevated ambient temperatures?

No — the 160 A rating holds flat from 40 °C through 70 °C ambient, so no thermal derating is needed across that range.

Where can I buy 3VA2216-7HL32-0AA0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA2216-7HL32-0AA0