Siemens 3VA2216-7HL42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7HL42-0AA0 SENTRON MCCB, 160 A, 4-Pole, ETU3

MPN3VA2216-7HL42-0AA0
Active

Siemens SENTRON 3VA2, molded case circuit breaker, 4-pole, 160 A rated continuous current, ETU320 electronic trip unit, line protection design, IP40 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-7HL42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2216-7HL42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-7HL42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2216-7HL42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-7HL42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-7HL42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-7HL42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

This 3VA2216-7HL42-0AA0 is a 4-pole SENTRON molded case circuit breaker from the 3VA2 series, rated for 160 A continuous current with an ETU320 electronic trip unit. It's designed for line protection — main feeder or large branch in a distribution panel. The trip unit is adjustable from 240 A to 1 920 A, so you set the actual protection threshold to match the downstream load.

The interrupting ratings are what make this breaker stand out for high-fault installations: 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V. That's enough SCCR headroom to coordinate with upstream transformers or downstream panelboards without cascading failure.

Bolts onto a mounting plate or into a panel cutout — no DIN-rail clip on this frame size.

Frequently asked questions

What is the closest functional second-source for 3VA2216-7HL42-0AA0?

The peer 3VA2116-5HL32-0AK0 is a 3-pole version with a different trip unit and lower interrupting ratings — it will not drop into a 4-pole panel without rewiring and does not match the 160 A continuous rating or the ETU320 trip curve. For a direct functional replacement, stick with the 4-pole 3VA2 frame.

What are the key dimensions of 3VA2216-7HL42-0AA0?

Width 140 mm, height 181 mm, depth 86 mm. Bolts onto a mounting plate — no DIN-rail clip on this frame.

Where can I buy 3VA2216-7HL42-0AA0?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing confirmed at quote time — no stock figures or lead-time numbers listed here.

MPN
3VA2216-7HL42-0AA0