Skip to main content
Siemens 3VA2216-7HM42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7HM42-0AA0 SENTRON MCCB, 160 A, 4-Pole, 330

MPN3VA2216-7HM42-0AA0
Active

Siemens SENTRON 3VA2216-7HM42-0AA0, molded case circuit breaker, 4-pole, 160 A continuous, line protection, breaking 330 kA at 240 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-7HM42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2216-7HM42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.19.7 W
3VA2216-7HM42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
Grounding protection functionYes
3VA2216-7HM42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-7HM42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2216-7HM42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-7HM42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

The Siemens SENTRON 3VA2216-7HM42-0AA0 is a 4-pole molded case circuit breaker (MCCB) rated for line protection, carrying a continuous current of 160 A across the full ambient range from 40 °C to 70 °C — no derating needed up to that ceiling. Its interrupting capacity hits 330 kA at 240 V, 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V — so on a 480 V panel it clears a 187 kA fault without cascading upstream. The adjustable thermal-magnetic trip is set with a minimum of 240 A and maximum of 1 920 A, giving you a wide coordination window for downstream feeders.

Ground-fault monitoring uses summation current formation on L + N, so it catches residual faults without a separate GFCI module — handy for a 4-wire system where you want to keep the neutral monitored.

Frequently asked questions

Will this part drop into a panel specified for 3VA2216-7MS32-0KC0?

Both are 4-pole SENTRON MCCBs with the same frame size, so the footprint and bus connections match. The key difference is the trip unit — the -7HM42-0AA0 is a line-protection thermal-magnetic; the -7MS32-0KC0 has a different trip curve. Verify the trip settings against your coordination study before swapping.

MPN