Skip to main content
Siemens 3VA2216-7MN32-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7MN32-0AB0 SENTRON MCCB, 160 A, 330 kA

MPN3VA2216-7MN32-0AB0

Siemens SENTRON 3VA2216-7MN32-0AB0, molded case circuit breaker, 3-pole, 160 A, 330 kA at 240 V, motor protection, ETU350M release.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

3VA2216-7MN32-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
Basic switch (supplied) ref.3VA2216-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11

Ratings

3VA2216-7MN32-0AB0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C153.6 A
Current at 60 °C150.4 A
Current at 65 °C147.2 A
Current at 70 °C144 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V52.5 kA
Power loss, max.75 W

Protection & Trip Unit

3VA2216-7MN32-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M

Construction & Connection

3VA2216-7MN32-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40

Accessories & Functions

3VA2216-7MN32-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2

Environmental

3VA2216-7MN32-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Mechanical

3VA2216-7MN32-0AB0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm

Product details

What this MCCB does on a motor branch

The Siemens SENTRON 3VA2216-7MN32-0AB0 is a 3-pole molded case circuit breaker rated for 160 A continuous current (Iu) at 40 °C, built specifically for motor protection — it includes phase failure detection and an ETU350M electronic overcurrent release that handles the inrush and overload profile of a motor start without nuisance tripping. Breaking capacity hits 330 kA at 240 V and 242 kA at 415 V, so it can interrupt a high-fault bolted short upstream without cascading to the main breaker — that is the kind of rating you spec when the transformer is right around the corner. Rated insulation voltage is 800 V, which covers 690 V line-to-line systems with margin; the front face carries IP40 protection, meaning it keeps tools and dust out of the mechanism in a closed panel.

Mounting and panel fit

Footprint is 105 mm wide by 181 mm tall by 86 mm deep — standard 3-pole MCCB envelope for a 160 A frame. It bolts to a mounting plate or backpanel; no DIN-rail clip on this class of breaker. Auxiliary contact version ships with 2 HP-rated auxiliary switches built in, so you get status feedback to the PLC without adding a separate contact block.

Frequently asked questions

What is the breaking capacity of this MCCB at 415 V?

242 kA at 415 V, which is the same rating as at 440 V; at 690 V it still holds 52.5 kA.

Where can I buy 3VA2216-7MN32-0AB0?

This part is sourced and quoted to order against an RFQ through independent distribution channels — availability and current pricing are confirmed at quote time.

What does the ETU350M release do?

The ETU350M is an electronic overcurrent release with motor-protection curves — it provides adjustable thermal and magnetic pickup, plus phase-failure detection, so it protects the motor without tripping on normal starting current.

MPN
3VA2216-7MN32-0AB0