Siemens 3VA2216-7MN32-0DL0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2216-7MN32-0DL0 SENTRON MCCB, 160 A, 3-Pole, 330

MPN3VA2216-7MN32-0DL0

Siemens SENTRON 3VA2216-7MN32-0DL0, molded case circuit breaker (MCCB), 3-pole, 160 A, breaking capacity 330 kA at 240 V, motor protection design, undervoltage release.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3VA2216-7MN32-0DL0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA2216-7MN32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB22
3VA2216-7MN32-0DL0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C160 A
Current at 60 °C160 A
Current at 65 °C160 A
Current at 70 °C160 A
Switching capacity classC
Breaking capacity at 240 V330 kA
Breaking capacity at 415 V242 kA
Breaking capacity at 440 V242 kA
Breaking capacity at 500 V187 kA
Breaking capacity at 690 V4.5 kA
Power loss, max.22.2 W
3VA2216-7MN32-0DL0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2216-7MN32-0DL0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2216-7MN32-0DL0 — Accessories & Functions
ParameterValue
Undervoltage releaseYes
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2216-7MN32-0DL0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2216-7MN32-0DL0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

Its 330 kA breaking capacity at 240 V AC means it can safely interrupt a fault current that high without upstream cascading; at 415 V and 440 V that figure holds at 242 kA, and at 690 V it drops to 4.5 kA. For motor protection duty, the breaker includes phase failure detection and an undervoltage release (UVR), so it trips on loss of phase or control voltage — a standard requirement for conveyor, pump, and compressor circuits.

The auxiliary switch block (2 aux switches + 1 trip alarm + 1 electrical alarm switch HQ) and the undervoltage release are factory-integrated on the basic switch 3VA2216-7MN32-0AA0, so no field assembly of add-on modules is needed. Trip indicator is present for quick visual fault identification on the line side.

Frequently asked questions

What is the breaking capacity of 3VA2216-7MN32-0DL0 at 240 V?

330 kA at 240 V AC, dropping to 242 kA at 415 V and 440 V, 187 kA at 500 V, and 4.5 kA at 690 V.

Where can I buy 3VA2216-7MN32-0DL0 and how is it quoted?

This breaker is sourced to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the closest functional second-source for 3VA2216-7MN32-0DL0?

The evidence lists 5SQ2370-2YA05, 5SQ2370-2YA04, and 5SQ2370-2YA01 as peer MPNs, but the 3VA2216-7MN32-0DL0 is a current-production SENTRON MCCB with specific auxiliary switch and release configuration — verify footprint and wiring before substituting.

MPN
3VA2216-7MN32-0DL0